| Main | ||||
| Part Number | LC1D245E7C | LC1D245F5C | LC1D245F7C | LC1D245M5C | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | Contactor | Contactor | 
| product short name | LC1D | LC1D | LC1D | LC1D | 
| Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | 
| use category | AC-1AC -3 | AC-1AC -3 | AC-3AC -1 | AC-1AC -3 | 
| number of poles | 3P | 3P | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | 
| Rated operating current [Ie] | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits | 
| [Uc] control circuit voltage | 48 V AC 50/60 Hz | 110V AC 50Hz | 110V AC 50/60Hz | 230V AC 50Hz | 
| Additional information | ||||
| Motor power (kW) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) | 
| model | LC1D | LC1D | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO | 
| protection cap | None | None | None | None | 
| Conventional thermal current [Ith] | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 
| Rated short-time withstand current [Icw] | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit | 
| Fuses for use with relays | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits | 
| average impedance | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | III | III | III | 
| pollution level | 3 | 3 | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 
| Mechanical life | 8 Mcycles | 8 Mcycles | 8 Mcycles | 8 Mcycles | 
| Electrical life | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V | 
| Control loop characteristics | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz | AC at 50 Hz | 
| Control voltage limit | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz | 
| (~50Hz pickup) power consumption (VA) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 805VA 50Hz (0.320°C) | 
| (~50Hz hold) power consumption (VA) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 55VA 50Hz (0.320°C) | 
| heat dissipation | 18…24W | 18…24W | 18…24W | 18…24W | 
| action time | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 
| operating frequency | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 
| Wiring capacity | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm | 
| Tightening torque | Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector | Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector | Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector | Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector | 
| Auxiliary contact type | Does not contain | Does not contain | Does not contain | Does not contain | 
| installation method | DIN rail installation base plate installation | Chassis mounting rail installation | Chassis mounting rail installation | DIN rail installation base plate installation | 
| environment | ||||
| standard | GB 14048.4 IEC 60947-4-1 | IEC 60947-4-1 GB 14048.4 | GB 14048.4 IEC 60947-4-1 | GB 14048.4 IEC 60947-4-1 | 
| certified product | CCC CE | CCC CE | CCC CE | CCC CE | 
| IP protection class | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | 
| high | 197 mm | 197 mm | 197 mm | 197 mm | 
| width | 168.5mm | 168.5mm | 168.5mm | 168.5mm | 
| depth | 181 mm | 181 mm | 181 mm | 181 mm | 
| Product Weight | 5.3kg | 5.3kg | 5.3kg | 5.3kg | 
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 21.0cm | 21.0cm | 21.0cm | 22.0cm | 
| Package 1 Width | 22.0cm | 22.0cm | 22.0cm | 21.7cm | 
| Package 1 Length | 23.5cm | 23.5cm | 23.5cm | 22.9 cm | 
| Package 1 Weight | 5401.0g | 5401.0g | 5401.0g | 5.157 kg | 
| Unit Type of Package 2 | P06 | P06 | P06 | PAL | 
| Number of Units in Package 2 | 12 | 12 | 12 | 12 | 
| Package 2 Height | 57.0cm | 57.0cm | 57.0cm | 42.0cm | 
| Package 2 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm | 
| Package 2 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm | 
| Package 2 Weight | 74.812kg | 74.812kg | 74.812kg | 66.684kg | 
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | |||
| Part Number | LC1D245M7C | LC1D245Q5C | LC1D245Q7C | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | Contactor | 
| product short name | LC1D | LC1D | LC1D | 
| Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | 
| use category | AC-1AC -3 | AC-3AC -1 | AC-1AC -3 | 
| number of poles | 3P | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC | 
| Rated operating current [Ie] | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits | 315 A 40 °C) at <= 440 V AC AC-1 for power circuits 245 A 40 °C) at <= 440 V AC AC-3 for power circuits | 
| [Uc] control circuit voltage | 230V AC 50/60Hz | 380V AC 50Hz | 380 V AC 50/60 Hz | 
| Additional information | |||
| Motor power (kW) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) | 75 kW at 220/240 V AC 50/60 Hz (AC-3) 132 kW at 380/400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660/690 V AC 50 /60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) | 
| model | LC1D | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 3 NO | 
| protection cap | None | None | None | 
| Conventional thermal current [Ith] | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 315 A at <40 °C for power circuits | 
| Rated short-time withstand current [Icw] | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit | 1800 A at <40 °C – 10 s for power circuit 1000 A at <40 °C – 30 s for power circuit 850 A at <40 °C – 1 min for power circuit 560 A at <40 °C – 3 minutes for power circuit 440 A at <40 °C – 10 minutes for power circuit | 
| Fuses for use with relays | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits | 315 A gG at <= 440 V for power circuits 250 A aM at <= 440 V for power circuits | 
| average impedance | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 0.32 mΩ – Ith 315 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | Power circuit: 1000 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | III | III | 
| pollution level | 3 | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 8 kV according to IEC 60947 | 
| Mechanical life | 8 Mcycles | 8 Mcycles | 8 Mcycles | 
| Electrical life | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V | 0.45 Mcycles 315 A AC-1 Ue <= 440 V 1 Mcycles 200 A AC-3 Ue <= 440 V 1 Mcycles 129 A AC-3 Ue 660/690 V | 
| Control loop characteristics | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz | 
| Control voltage limit | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 0.85…1.15 Uc -5…55 °C operating 50 Hz 0.35…0.55 Uc -5…55 °C releasing 50 Hz | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz | 
| (~50Hz pickup) power consumption (VA) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 805VA 50Hz (0.320°C) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) | 
| (~50Hz hold) power consumption (VA) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 55VA 50Hz (0.320°C) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) | 
| heat dissipation | 18…24W | 18…24W | 18…24W | 
| action time | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 20…35 ms closed 7…15 ms open | 
| operating frequency | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 2400 cycles/h at <55 °C | 
| Wiring capacity | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire Terminals Power Circuit: Terminal Connector Cable Selection: Stranded Wire with Wire Terminals Control Circuit: Bolt Fastened Cable Selection: Solid Wire Without Wire Terminals Power Circuit: Busbar Terminals Cable Selection: Hard Wire Cross-section of busbars without wire terminals: 32 x 4 mm | 
| Tightening torque | Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector | Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector | Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm Power circuit via busbar terminals: 35 Nm via cable connector | 
| Auxiliary contact type | Does not contain | Does not contain | Does not contain | 
| installation method | Chassis mounting rail installation | DIN rail installation base plate installation | DIN rail installation base plate installation | 
| environment | |||
| standard | IEC 60947-4-1 GB 14048.4 | GB 14048.4 IEC 60947-4-1 | GB 14048.4 IEC 60947-4-1 | 
| certified product | CCC CE | CCC CE | CCC CE | 
| IP protection class | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | IP20 front panel with LA9F conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 3000 m None | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 | 
| high | 197 mm | 197 mm | 197 mm | 
| width | 168.5mm | 168.5mm | 168.5 mm | 
| depth | 181 mm | 181 mm | 181 mm | 
| Product Weight | 5.3kg | 5.3kg | 5.3 kg | 
| packaging unit | |||
| Unit Type of Package 1 | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 
| Package 1 Height | 22.0cm | 21.595 cm | 21.73 cm | 
| Package 1 Width | 21.5cm | 23.859 cm | 22.6 cm | 
| Package 1 Length | 23.1 cm | 22.462 cm | 23.641 cm | 
| Package 1 Weight | 5.168 kg | 5.25 kg | 5.281kg | 
| Unit Type of Package 2 | PAL | PAL | PAL | 
| Number of Units in Package 2 | 12 | 12 | 12 | 
| Package 2 Height | 42.0cm | 42.0cm | 42.0cm | 
| Package 2 Width | 60.0cm | 60.0cm | 60.0cm | 
| Package 2 Length | 80.0cm | 80.0cm | 80.0cm | 
| Package 2 Weight | 66.84kg | 66.0kg | 66.0kg | 
| contract warranty | |||
| Warranty | 18 months | 18 months | 18 months | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |