| Main | ||||
| Part Number | LC1D38B7C | LC1D38BDC | LC1D38CC7C | LC1D38E7C | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | Contactor | Contactor | 
| product short name | LC1D | LC1D | LC1D | LC1D | 
| Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | 
| use category | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | 
| number of poles | 3P | 3P | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC | 
| Rated operating current [Ie] | 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 38 A 60 °C) at <= 440 V AC AC-3 for power circuit 38 A 60 °C) at< = 440 V AC AC-3e for power circuit | 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 38 A 60 °C) at <= 440 V AC AC-3 for power circuit 38 A 60 °C) at< = 440 V AC AC-3e for power circuit | 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 38 A 60 °C) at <= 440 V AC AC-3 for power circuit 38 A 60 °C) at< = 440 V AC AC-3e for power circuit | 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 38 A 60 °C) at <= 440 V AC AC-3 for power circuit 38 A 60 °C) at< = 440 V AC AC-3e for power circuit | 
| [Uc] control circuit voltage | 24 V AC 50/60 Hz | 24 V DC | 36 V AC 50/60 Hz | 48 V AC 50/60 Hz | 
| Additional information | ||||
| Motor power (kW) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC -4) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 9 kW at 220/240 V AC 50/60 Hz (AC-3) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) 18.5 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 9 kW at 220/240 V AC 50/60 Hz (AC-3e) 18.5 kW at 415/440 V AC 50/60 Hz (AC -3e) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 9 kW at 220/240 V AC 50/60 Hz (AC-3) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e) 9 kW at 220/240 V AC 50/60 Hz (AC-3e) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3e) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 9 kW at 220/240 V AC 50/60 Hz (AC-3) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e) 9 kW at 220/240 V AC 50/60 Hz (AC-3e) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3e) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 9 kW at 220/240 V AC 50/60 Hz (AC-3) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e) 9 kW at 220/240 V AC 50/60 Hz (AC-3e) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3e) | 
| model | LC1D | LC1D | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO | 
| protection cap | None | None | None | None | 
| Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits | 
| Rated short-time withstand current [Icw] | 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 150 A at <40 °C – 1 min for power circuit 310 A at <40 °C – 10 s for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 150 A at <40 °C – 1 min for power circuit 310 A at <40 °C – 10 s for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 150 A at <40 °C – 1 min for power circuit 310 A at <40 °C – 10 s for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 150 A at <40 °C – 1 min for power circuit 310 A at <40 °C – 10 s for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 
| Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V | 
| average impedance | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 | 
| Overvoltage category | III | III | III | III | 
| pollution level | 3 | 3 | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 
| Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | 
| Mechanical life | 15 Mcycles | 30 Mcycles | 15 Mcycles | 15 Mcycles | 
| Electrical life | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.4 Mcycles 37 A AC-3 Ue <= 440 V 1.4 Mcycles 37 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.4 Mcycles 37 A AC-3 Ue <= 440 V 1.4 Mcycles 37 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.4 Mcycles 37 A AC-3 Ue <= 440 V 1.4 Mcycles 37 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.4 Mcycles 37 A AC-3 Ue <= 440 V 1.4 Mcycles 37 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue | 
| Control loop characteristics | AC at 50/60 Hz | DC standard | AC at 50/60 Hz | AC at 50/60 Hz | 
| Surge Suppression Module | No built-in surge suppression module | Built-in bidirectional peak current limiting diode | No built-in surge suppression module | No built-in surge suppression module | 
| Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz | 0.1…0.25 Uc -40…60 °C release 0.7…1.25 Uc -40…60 °C run | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz | 
| (~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) | |
| (~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) | |
| heat dissipation | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | |
| action time | 12…22 ms close 4…19 ms break | 55 ms to close, 20 ms to break | 12…22 ms close 4…19 ms break | 12…22 ms close 4…19 ms break | 
| operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 
| Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal | 
| Tightening torque | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 | 
| Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 
| Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 
| Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz | 
| Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 
| Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | 
| non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 
| installation method | Chassis mounting rail installation | Chassis mounting rail installation | Chassis mounting rail installation | DIN rail installation base plate installation | 
| environment | ||||
| standard | GB 14048.4 IEC 60947-4-1 | GB 14048.4 IEC 60947-4-1 | IEC 60947-4-1 GB 14048.4 | IEC 60947-4-1 GB 14048.4 | 
| certified product | CCC CE UKCA | CCC CE UKCA | CCC CE UKCA | CCC CE UKCA | 
| IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None | 
| Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 | 
| high | 85 mm | 85 mm | 85 mm | 85 mm | 
| width | 45 mm | 45 mm | 45 mm | 45 mm | 
| depth | 92 mm | 101 mm | 92 mm | 92 mm | 
| Product Weight | 0.38 kg | 0.38kg | 0.38kg | 0.38kg | 
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 5.359 cm | 5.41 cm | 8.8cm | 8.8cm | 
| Package 1 Width | 8.874 cm | 8.82cm | 9.9 cm | 9.9 cm | 
| Package 1 Length | 10.12cm | 10.898 cm | 5.1 cm | 5.1 cm | 
| Package 1 Weight | 410.0g | 580.0g | 391.48g | 391.48g | 
| Unit Type of Package 2 | S02 | S02 | CAR | CAR | 
| Number of Units in Package 2 | Twenty one | 20 | Twenty one | Twenty one | 
| Package 2 Height | 15.0cm | 15.0cm | 30.0cm | 30.0cm | 
| Package 2 Width | 30.0cm | 30.0cm | 40.0cm | 40.0cm | 
| Package 2 Length | 40.0cm | 40.0cm | 15.0cm | 15.0cm | 
| Package 2 Weight | 9.141kg | 12.091kg | 8.271kg | 8.271kg | 
| Unit Type of Package 3 | PAL | PAL | PAL | PAL | 
| Number of Units in Package 3 | 336 | 320 | 336 | 336 | 
| Package 3 Height | 60.0cm | 60.0cm | 60.0cm | 60.0cm | 
| Package 3 Width | 80.0cm | 80.0cm | 80.0cm | 80.0cm | 
| Package 3 Length | 75.0cm | 75.0cm | 75.0cm | 75.0cm | 
| Package 3 Weight | 146.016kg | 199.024kg | 131.736 kg | 131.736 kg | 
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | |||
| Part Number | LC1D38F7C | LC1D38M7C | LC1D38Q7C | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | Contactor | 
| product short name | LC1D | LC1D | LC1D | 
| Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | 
| use category | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | 
| number of poles | 3P | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC | 
| Rated operating current [Ie] | 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 38 A 60 °C) at <= 440 V AC AC-3 for power circuit 38 A 60 °C) at< = 440 V AC AC-3e for power circuit | 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 38 A 60 °C) at <= 440 V AC AC-3 for power circuit 38 A 60 °C) at< = 440 V AC AC-3e for power circuit | 50 A 60 °C) at <= 440 V AC AC-1 for power circuit 38 A 60 °C) at <= 440 V AC AC-3 for power circuit 38 A 60 °C) at< = 440 V AC AC-3e for power circuit | 
| [Uc] control circuit voltage | 110V AC 50/60Hz | 230V AC 50/60Hz | 380 V AC 50/60 Hz | 
| Additional information | |||
| Motor power (kW) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 9 kW at 220/240 V AC 50/60 Hz (AC-3) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e) 9 kW at 220/240 V AC 50/60 Hz (AC-3e) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3e) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC -4) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 9 kW at 220/240 V AC 50/60 Hz (AC-3) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) 18.5 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 9 kW at 220/240 V AC 50/60 Hz (AC-3e) 18.5 kW at 415/440 V AC 50/60 Hz (AC -3e) | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC -4) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 9 kW at 220/240 V AC 50/60 Hz (AC-3) 18.5 kW at 415/440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e) 18.5 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 9 kW at 220/240 V AC 50/60 Hz (AC-3e) 18.5 kW at 415/440 V AC 50/60 Hz (AC -3e) | 
| model | LC1D | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 3 NO | 
| protection cap | None | None | None | 
| Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 50 A at <60 °C for power circuits | 
| Rated short-time withstand current [Icw] | 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 150 A at <40 °C – 1 min for power circuit 310 A at <40 °C – 10 s for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 150 A at <40 °C – 1 min for power circuit 310 A at <40 °C – 10 s for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 430 A at <40 °C – 1 s for power circuit 60 A at <40 °C – 10 min for power circuit 150 A at <40 °C – 1 min for power circuit 310 A at <40 °C – 10 s for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 
| Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V | 10 A gG for signal circuits according to IEC 60947-5-1 63 A gG at <= 690 V for power circuits type 1 63 A gG for power circuits for type 2 at <= 690 V | 
| average impedance | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 2 mΩ – Ith 50 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 | 
| Overvoltage category | III | III | III | 
| pollution level | 3 | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 
| Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | 
| Mechanical life | 15 Mcycles | 15 Mcycles | 15 Mcycles | 
| Electrical life | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.4 Mcycles 37 A AC-3 Ue <= 440 V 1.4 Mcycles 37 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.4 Mcycles 37 A AC-3 Ue <= 440 V 1.4 Mcycles 37 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue | 1.4 Mcycles 50 A AC-1 Ue <= 440 V 2.6 Mcycles 22 A AC-3 Ue 660/690 V 1.4 Mcycles 37 A AC-3 Ue <= 440 V 1.4 Mcycles 37 A AC-3e Ue <= 440 V at 2.6 Mcycles 22 A AC-3e at 660/690 V at Ue | 
| Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz | 
| Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | 
| Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz | 
| (~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) | 
| (~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) | 
| heat dissipation | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 
| action time | 12…22 ms close 4…19 ms break | 12…22 ms close 4…19 ms break | 12…22 ms close 4…19 ms break | 
| operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 
| Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt tight2 1…4 mm² Cable selection: Hard wire without wire terminal Power circuit: Bolt fastened1 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable Size selection: flexible cord without wire terminals Power circuit: screw fastening2 2.5…10 mm² Lug outer diameter Ø: 10 mm Cable selection: flexible wire without wire terminal Power circuit: screw tight1 1…10 mm² Lug outer diameter Ø: 10 mm Cable option: flexible cord with wire terminal Power circuit: screw fastening2 1.5…6 mm² Lug outer diameter Ø: 10 mm Cable option: Flexible cord with wire terminal Power circuit : Bolt fastening1 1.5…10 mm² Lug O.D. Ø: 10 mm Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 10 mm Cable selection : Hard wire without wire terminal | 
| Tightening torque | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No 2 Phillips screw power circuit: 2.5 Nm via screwdriver Ø 6 flat power circuit: 2.5 Nm via screw Screwdriver No. 2 for fastening Phillips screw : 2.5 Nm Screwdriver Ø 6 flat-blade screw for cable connector: M4 Power circuit: 2.5 Nm Phillips screw for cable connector No. 2 screw: M4 Power circuit: 2.5 Nm Tightening with bolts Control circuit with screwdriver pozidriv No 2 : 1.7 Nm Tighten by screw with screwdriver pozidriv No 2 | 
| Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 
| Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 | 1 NO + 1 NC | 1 NO + 1 NC | 
| Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 
| Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 
| Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | 
| non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 
| installation method | Chassis mounting rail installation | DIN rail installation base plate installation | Chassis mounting rail installation | 
| environment | |||
| standard | IEC 60947-4-1 GB 14048.4 | IEC 60947-4-1 GB 14048.4 | GB 14048.4 IEC 60947-4-1 | 
| certified product | CCC CE UKCA | CCC CE UKCA | CCC CE UKCA | 
| IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 3000 m None | 
| Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 | 
| high | 85 mm | 85 mm | 85 mm | 
| width | 45 mm | 45 mm | 45 mm | 
| depth | 92 mm | 92 mm | 92 mm | 
| Product Weight | 0.38 kg | 0.38 kg | 0.38kg | 
| packaging unit | |||
| Unit Type of Package 1 | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 
| Package 1 Height | 5.359 cm | 5.112 cm | 5.564 cm | 
| Package 1 Width | 8.765 cm | 8.836 cm | 8.984 cm | 
| Package 1 Length | 10.073 cm | 10.029 cm | 9.946 cm | 
| Package 1 Weight | 410.0g | 410.0g | 410.0g | 
| Unit Type of Package 2 | S02 | S02 | S02 | 
| Number of Units in Package 2 | Twenty one | Twenty one | Twenty one | 
| Package 2 Height | 15.0cm | 15.0cm | 15.0cm | 
| Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 
| Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 
| Package 2 Weight | 9.03kg | 9.03kg | 9.04kg | 
| Unit Type of Package 3 | PAL | PAL | PAL | 
| Number of Units in Package 3 | 336 | 336 | 336 | 
| Package 3 Height | 60.0cm | 60.0cm | 60.0cm | 
| Package 3 Width | 80.0cm | 80.0cm | 80.0cm | 
| Package 3 Length | 75.0cm | 75.0cm | 75.0cm | 
| Package 3 Weight | 143.573 kg | 148.704kg | 147.776kg | 
| contract warranty | |||
| Warranty | 18 months | 18 months | 18 months | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |