| Main | 
| Part Number | LC1D475M7C | 
| Product Series | TeSys Deca | 
| Product Series | TeSys Deca | 
| product type | Contactor | 
| product short name | LC1D | 
| Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 | 
| Applied to non-inductive or slightly inductive loads, resistance furnaces | 
| use category | AC-1AC | 
| -3 | 
| number of poles | 3P | 
| Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz | 
| Power circuit: <= 460 V DC | 
| Rated operating current [Ie] | 700 A 40 °C) at <= 440 V AC AC-1 for power circuits | 
| 475 A 40 °C) at <= 440 V AC AC-3 for power circuits | 
| [Uc] control circuit voltage | 230V AC 50/60Hz | 
| Additional information | 
| Motor power (kW) | 147 kW at 220/240 V AC 50/60 Hz (AC-3) | 
| 265 kW at 380/400 V AC 50/60 Hz (AC-3) | 
| 280 kW at 415 V AC 50/60 Hz (AC-3) | 
| 280 kW at 440 V AC 50/60 Hz (AC-3) | 
| 355 kW at 500 V AC 50/60 Hz (AC-3) | 
| 335 kW at 660/690 V AC 50 /60 Hz (AC-3) | 
| 335 kW at 1000 V AC 50/60 Hz (AC-3) | 
| model | LC1D | 
| Loop contact type | 3 NO | 
| protection cap | None | 
| Conventional thermal current [Ith] | 700 A at <40 °C for power circuits | 
| Rated short-time withstand current [Icw] | 4200 A at <40 °C – 10 s for power circuit | 
| 3200 A at <40 °C – 30 s for power circuit | 
| 2400 A at <40 °C – 1 min for power circuit | 
| 1500 A at <40 °C – 3 minutes for power circuits | 
| 1200 A at <40 °C – 10 minutes for power circuits | 
| Fuses for use with relays | 500 A aM at <= 440 V for power circuits | 
| 800 A gG at <= 440 V for power circuits | 
| average impedance | 0.18 mΩ – Ith 700 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | 
| pollution level | 3 | 
| Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 
| Mechanical life | 8 Mcycles | 
| Electrical life | 0.4 Mcycles 700 A AC-1 Ue <= 440 V | 
| 0.9 Mcycles 460 A AC-3 Ue <= 440 V | 
| 0.7 Mcycles 355 A AC-3 Ue 660/690 V | 
| Control loop characteristics | AC at 50/60 Hz | 
| Control voltage limit | 0.3…0.5 Uc -5…55 °C release 40…400 Hz | 
| 0.85…1.1 Uc -5…55 °C run 40…400 Hz | 
| (~50Hz pickup) power consumption (VA) | 1100 VA 50 Hz 0.9 20 °C) | 
| 1100 VA 60 Hz 0.9 20 °C) | 
| (~50Hz hold) power consumption (VA) | 18VA 50Hz 0.9 20°C) | 
| 18VA 60Hz 0.9 20°C) | 
| heat dissipation | 18W | 
| action time | 100…170 ms open | 
| 40…75 ms close | 
| operating frequency | 2400 cycles/h at <55 °C | 
| Wiring capacity | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal | 
| Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal | 
| Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals | 
| Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals | 
| Power circuit: Bus terminal | 
| Tightening torque |  | 
| Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm | 
| Power circuit via busbar terminals: 35 Nm via cable connector | 
| Auxiliary contact type | Does not contain | 
| installation method | Rail installation | 
| environment | 
| standard | IEC 60947-4-1 | 
| GB 14048.4 | 
| certified product | CCC | 
| CE | 
| ambient air temperature | -40…60 °C operation | 
| 60…70 °C with derating | 
| -60…80 °C storage | 
| working altitude | 3000 m None | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 | 
| gn (5…300 Hz)) conforming to IEC 60068-2-6 | 
| Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 | 
| Shock resistance 11 ms with contacts open (9 gn) conforming to IEC 60068-2-27 | 
| high | 238 mm | 
| width | 233 mm | 
| depth | 232 mm | 
| Product Weight | 12.5 kg | 
| packaging unit | 
| Unit Type of Package 1 | PCE | 
| Number of Units in Package 1 | 1 | 
| Package 1 Height | 26.7 cm | 
| Package 1 Width | 28.0cm | 
| Package 1 Length | 33.0cm | 
| Package 1 Weight | 11.62kg | 
| Unit Type of Package 2 | PAL | 
| Number of Units in Package 2 | 8 | 
| Package 2 Height | 50.0cm | 
| Package 2 Width | 60.0cm | 
| Package 2 Length | 80.0cm | 
| Package 2 Weight | 93.936 kg | 
| contract warranty | 
| Warranty | 18 months |