| Main | 
| Part Number | LC1D115004M7 | 
| Product Series | TeSys | 
| Product Series | TeSys Deca | 
| product type | Contactor | 
| product short name | LC1D | 
| Application field of contactor | Applied to non-inductive or micro-inductive load, resistance furnace | 
| use category | AC-1 | 
| number of poles | 4P | 
| Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz | 
| Power circuit: <= 460 V DC | 
| Rated operating current [Ie] | 200 A 60 °C) at <= 440 V AC AC-1 for power circuits | 
| [Uc] control circuit voltage | 230V AC 50/60Hz | 
| Additional information | 
| model | LC1D | 
| Loop contact type | 4 NO | 
| Contactor Compatibility Features | M14 | 
| protection cap | Bring | 
| Conventional thermal current [Ith] | 200 A at <60 °C for power circuits | 
| Rated making capacity [Irms] | 1260 A at 440 V for power circuits conforming to IEC 60947 | 
| Rated breaking capacity | 1100 A at 440 V for power circuits conforming to IEC 60947 | 
| Rated short-time withstand current [Icw] | 250 A at <40 °C – 10 min for power circuit | 
| 550 A at <40 °C – 1 min for power circuit | 
| 950 A at <40 °C – 10 s for power circuit | 
| 1100 A at <40 °C – 1 s for power circuits | 
| Fuses for use with relays | 250 A gG at <= 690 V with type 1 suitable power circuit | 
| 200 A gG at <= 690 V with type 2 suitable power circuit | 
| average impedance | 0.6 mΩ – Ith 200 A 50 Hz for power circuits | 
| power consumption per pole | 24W AC-1 | 
| Rated insulation voltage [Ui] | Power circuit: 600 V CSA certified | 
| Power circuit: 600 V UL certified | 
| Power circuit: 1000 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | 
| pollution level | 3 | 
| Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 | 
| Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 | 
| B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | 
| Mechanical life | 8 Mcycles | 
| Electrical life | 0.8 Mcycles <= 440 V at 200 A AC-1 Ue | 
| Control loop characteristics | AC at 50/60 Hz | 
| Surge Suppression Module | Built-in bidirectional peak current limiting diode | 
| Control voltage limit | 0.3…0.5 Uc -40…70 °C Release AC 50/60 Hz | 
| 0.8…1.15 Uc -40…55 °C Run AC 50/60 Hz | 
| 1…1.15 Uc 55…70 °C Run AC 50 /60Hz | 
| (~50Hz pickup) power consumption (VA) | 280…350 VA 60 Hz 0.8 20 °C) | 
| 280…350 VA 50 Hz 0.8 20 °C) | 
| (~50Hz hold) power consumption (VA) | 2…18 VA 60 Hz 0.3 20 °C) | 
| 2…18 VA 50 Hz 0.3 20 °C) | 
| heat dissipation | 3…8 W at 50/60 Hz | 
| action time | 6…20 ms open | 
| 20…50 ms close | 
| operating frequency | 2400 cycles/h at <60 °C | 
| Wiring capacity | Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal | 
| Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire with wire terminal | 
| Control circuit: Bolt fastening1 1 …2.5 mm² Cable option: flexible without wire terminals | 
| Control circuit: screw tight2 1…2.5 mm² Cable option: flexible without cable terminals | 
| Control circuit: screw tight1 1…2.5 mm² Cable option : Solid without wire terminals | 
| Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Hard wire without wire terminals | 
| Power circuit: Terminal 1 10…120 mm² Cable selection: Flexible wire without wire Terminals | 
| Power circuit: Terminal 2 10…50 mm² Cable option: Flexible cord without wire terminal | 
| Power circuit: Terminal 1 10…120 mm² Cable option: Flexible cord with cable terminal | 
| Power circuit: Terminal 2 10… 50 mm² Cable option: Flexible with wire terminals Power | 
| circuit: Terminal 1 10…120 mm² Cable option: Solid without wire terminals | 
| Power circuit: Terminal 2 10…50 mm² Cable option: Solid No With wire terminal | 
| Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat | 
| Control circuit: 1.2 Nm via screwdriver No. 2 Phillips screw | 
| power supply circuit: 12 Nm via terminal hex 4 mm | 
| control circuit: 1.2 Nm via screwdriver With a screwdriver pozidriv No 2 | 
| installation method | DIN rail installation | 
| base plate installation | 
| environment | 
| standard | CSA C22.2 No 14 | 
| EN 60947-4-1 | 
| EN 60947-5-1 | 
| IEC 60947-4-1 | 
| IEC 60947-5-1 | 
| UL 508 | 
| certified product | CCC | 
| RINA | 
| GOST | 
| UL | 
| CSA | 
| LROS (Lloyds register of shipping) | 
| BV | 
| GL | 
| DNV | 
| UKCA | 
| IP protection class | IP20 front panel complies with screwed | 
| Protective measures | TH conforms to IEC 60068-2-30 | 
| climate tolerance | Complies with IACS E10 for exposure to hot flashes | 
| Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes | 
| ambient air temperature | -40…60 °C | 
| 60…70 °C with derating | 
| working altitude | 0…3000 m | 
| Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 
| flame retardant | V1 complies with UL 94 | 
| Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) | 
| shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance | 
| with contacts closed (15 gn (11ms)) | 
| Shock performance Contact opening (6 gn (11ms)) | 
| high | 158 mm | 
| width | 150 mm | 
| depth | 132 mm | 
| Product Weight | 2.86kg | 
| packaging unit | 
| Unit Type of Package 1 | PCE | 
| Number of Units in Package 1 | 1 | 
| Package 1 Height | 19.500 cm | 
| Package 1 Width | 21.000 cm | 
| Package 1 Length | 21.000 cm | 
| Package 1 Weight | 2.971kg | 
| Unit Type of Package 2 | P06 | 
| Number of Units in Package 2 | 18 | 
| Package 2 Height | 75.000 cm | 
| Package 2 Width | 60.000 cm | 
| Package 2 Length | 80.000 cm | 
| Package 2 Weight | 66.478 kg | 
| contract warranty | 
| Warranty | 18 months |