| Main | ||||
| Part Number | LC1D95B7C | LC1D95CC5C | LC1D95E7C | LC1D95F7C | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | Contactor | Contactor | 
| product short name | LC1D | LC1D | LC1D | LC1D | 
| Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | 
| use category | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | 
| number of poles | 3P | 3P | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz | 
| Rated operating current [Ie] | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit | 
| [Uc] control circuit voltage | 24 V AC 50/60 Hz | 36V AC 50Hz | 48 V AC 50/60 Hz | 110V AC 50/60Hz | 
| Additional information | ||||
| Motor power (kW) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 25 kW at 220/240 V AC 50/60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415 /440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e ) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) | 
| model | LC1D | LC1D | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO | 
| protection cap | None | None | None | None | 
| Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits | 
| Rated short-time withstand current [Icw] | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 
| Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits | 
| average impedance | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | III | III | III | 
| pollution level | 3 | 3 | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 
| Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | 
| Mechanical life | 4 Mcycles | 4 Mcycles | 4 Mcycles | 4 Mcycles | 
| Electrical life | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue | 
| Control loop characteristics | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz | AC at 50/60 Hz | 
| Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | 
| Control voltage limit | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz | 0.3…0.6 Uc -40…55 °C release 50 Hz 0.85…1.1 Uc -40…55 °C run 50 Hz | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz | 
| (~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) | 200VA 50Hz (0.75 20°C) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) | 
| (~50Hz hold) power consumption (VA) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) | 20VA 50Hz 0.3 20°C) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) | 
| heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 
| action time | 20…35 ms close 6…20 ms break | 20…35 ms close 6…20 ms break | 20…35 ms close 6…20 ms break | 20…35 ms close 6…20 ms break | 
| operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 
| Wiring capacity | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals | 
| Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 | 
| Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 
| Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 
| Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz | 
| Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 
| Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | 
| non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 
| installation method | DIN rail installation base plate installation | DIN rail installation base plate installation | Chassis mounting rail installation | DIN rail installation base plate installation | 
| environment | ||||
| standard | IEC 60947-4-1 GB 14048.4 | IEC 60947-4-1 GB 14048.4 | IEC 60947-4-1 GB 14048.4 | GB 14048.4 IEC 60947-4-1 | 
| certified product | CCC CE UKCA | CCC CE UKCA | CCC CE UKCA | CCC CE UKCA | 
| IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None | 
| Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 
| Shock and vibration resistance | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 | 
| high | 127 mm | 127 mm | 127mm | 127 mm | 
| width | 85 mm | 85 mm | 85 mm | 85 mm | 
| depth | 130 mm | 130 mm | 130 mm | 130mm | 
| Product Weight | 1.61kg | 1.61kg | 1.61kg | 1.61kg | 
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 11.28cm | 15.0cm | 11.076 cm | 11.123 cm | 
| Package 1 Width | 15.212 cm | 11.1 cm | 14.915 cm | 15.17cm | 
| Package 1 Length | 16.022 cm | 15.7cm | 15.762 cm | 15.92cm | 
| Package 1 Weight | 1.571kg | 1584.7g | 1.581kg | 1.579kg | 
| Unit Type of Package 2 | CAR | CAR | CAR | CAR | 
| Number of Units in Package 2 | 5 | 5 | 5 | 5 | 
| Package 2 Height | 19.2 cm | 20.0cm | 19.3 cm | 19.9 cm | 
| Package 2 Width | 29.5cm | 30.0cm | 29.7 cm | 28.7 cm | 
| Package 2 Length | 40.2 cm | 40.0cm | 40.7 cm | 39.8 cm | 
| Package 2 Weight | 8.271kg | 8.38 kg | 8.33kg | 8.312kg | 
| Unit Type of Package 3 | PAL | P06 | PAL | PAL | 
| Number of Units in Package 3 | 60 | 60 | 60 | 60 | 
| Package 3 Height | 75.0cm | 75.0cm | 75.0cm | 75.0cm | 
| Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm | 
| Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm | 
| Package 3 Weight | 104.016kg | 110.56kg | 104.7kg | 104.388 kg | 
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | ||
| Part Number | LC1D95M7C | LC1D95Q7C | 
| Product Series | TeSys Deca | TeSys Deca | 
| Product Series | TeSys Deca | TeSys Deca | 
| product type | Contactor | Contactor | 
| product short name | LC1D | LC1D | 
| Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces | 
| use category | AC-4 AC-1 AC-3 AC-3e | AC-4 AC-1 AC-3 AC-3e | 
| number of poles | 3P | 3P | 
| Rated working voltage [Ue] | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz | 
| Rated operating current [Ie] | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit | 
| [Uc] control circuit voltage | 230V AC 50/60Hz | 380 V AC 50/60 Hz | 
| Additional information | ||
| Motor power (kW) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) | 
| model | LC1D | LC1D | 
| Loop contact type | 3 NO | 3 NO | 
| protection cap | None | None | 
| Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits | 
| Rated short-time withstand current [Icw] | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit | 
| Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits | 
| average impedance | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 
| Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 | 
| Overvoltage category | III | III | 
| pollution level | 3 | 3 | 
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 
| Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | 
| Mechanical life | 4 Mcycles | 4 Mcycles | 
| Electrical life | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue | 
| Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | 
| Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | 
| Control voltage limit | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz | 
| (~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) | 
| (~50Hz hold) power consumption (VA) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) | 
| heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 
| action time | 20…35 ms close 6…20 ms break | 20…35 ms close 6…20 ms break | 
| operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 
| Wiring capacity | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals | 
| Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 | 
| Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 
| Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 | 1 NO + 1 NC | 
| Signal loop frequency | 25…400Hz | 25…400Hz | 
| Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 
| Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | 
| non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts | 
| installation method | DIN rail installation base plate installation | Chassis mounting rail installation | 
| environment | ||
| standard | IEC 60947-4-1 GB 14048.4 | GB 14048.4 IEC 60947-4-1 | 
| certified product | CCC CE UKCA | CCC CE UKCA | 
| IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 | 
| Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | 
| ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | -40…60 °C operation 60…70 °C with derating -60…80 °C storage | 
| working altitude | 3000 m None | 3000 m None | 
| Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 
| Shock and vibration resistance | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 | 
| high | 127 mm | 127mm | 
| width | 85 mm | 85 mm | 
| depth | 130mm | 130mm | 
| Product Weight | 1.61kg | 1.61kg | 
| packaging unit | ||
| Unit Type of Package 1 | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 
| Package 1 Height | 11.5cm | 11.5cm | 
| Package 1 Width | 14.7 cm | 14.5cm | 
| Package 1 Length | 15.5cm | 15.4 cm | 
| Package 1 Weight | 1.588 kg | 1.628 kg | 
| Unit Type of Package 2 | CAR | CAR | 
| Number of Units in Package 2 | 5 | 5 | 
| Package 2 Height | 20.4cm | 19.7cm | 
| Package 2 Width | 28.9 cm | 28.9 cm | 
| Package 2 Length | 39.6 cm | 39.7 cm | 
| Package 2 Weight | 8.366 kg | 8.323kg | 
| Unit Type of Package 3 | PAL | PAL | 
| Number of Units in Package 3 | 60 | 60 | 
| Package 3 Height | 75.0cm | 75.0cm | 
| Package 3 Width | 60.0cm | 60.0cm | 
| Package 3 Length | 80.0cm | 80.0cm | 
| Package 3 Weight | 105.396kg | 99.156 kg | 
| contract warranty | ||
| Warranty | 18 months | 18 months | 
| Weight | N/A | 
|---|---|