| Main |
| Part Number |
GV3P40 |
GV3P50 |
GV3P65 |
| Range |
TeSys Deca |
TeSys Deca |
TeSys Deca |
| Product name |
TeSys GV3 |
TeSys GV3 |
TeSys GV3 |
| TeSys Deca |
TeSys Deca |
TeSys Deca |
| Product or component type |
Motor circuit breaker |
Motor circuit breaker |
Motor circuit breaker |
| Device short name |
GV3P |
GV3P |
GV3P |
| Device application |
Motor protection |
Motor protection |
Motor protection |
| Trip unit technology |
Thermal-magnetic |
Thermomagnetic |
Thermomagnetic |
| Complementary |
| Poles description |
3P |
3P |
3P |
| Network type |
AC |
AC |
AC |
| utilisation category |
AC-3 conforming to IEC 60947-4-1 |
AC-3 conforms to IEC 60947-4-1 |
AC-3 conforms to IEC 60947-4-1 |
| network frequency |
50/60 Hz conforming to IEC 60947-4-1 |
50/60 Hz conforming to IEC 60947-4-1 |
50/60 Hz conforming to IEC 60947-4-1 |
| fixing mode |
35 mm symmetrical DIN rail: clipped |
35 mm DIN rail: clipped |
35 mm DIN rail: clipped |
| Panel: screwed (with 3 x M4 screws) |
Panel: screw type (with 3 x M4 screws) |
Panel: screw type (with 3 x M4 screws) |
| motor power kW |
18.5 kW at 400/415 V AC 50/60 Hz |
22 kW at 400/415 V AC 50/60 Hz |
30 kW at 400/415 V AC 50/60 Hz |
| 22 kW at 500 V AC 50/60 Hz |
30 kW at 500 V AC 50/60 Hz |
45 kW at 500 V AC 50/60 Hz |
| 37 kW at 690 V AC 50/60 Hz |
45 kW at 690 V AC 50/60 Hz |
55 kW at 690 V AC 50/60 Hz |
| breaking capacity |
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
50 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2 |
50 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2 |
| 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity |
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type |
Rotary handle |
Rotary handle |
Rotary handle |
| [In] rated current |
40 A |
50A |
65A |
| thermal protection adjustment range |
30…40 A conforming to IEC 60947-4-1 |
37…50 A conforming to IEC 60947-4-1 |
48…65 A conforming to IEC 60947-4-1 |
| Magnetic tripping current |
560 A |
700A |
910A |
| [Ith] conventional free air thermal current |
40 A conforming to IEC 60947-4-1 |
50 A conforming to IEC 60947-4-1 |
65 A conforming to IEC 60947-4-1 |
| [Ue] rated operational voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-2 |
6 kV according to IEC 60947-2 |
6 kV according to IEC 60947-2 |
| phase failure sensitivity |
Yes conforming to IEC 60947-4-1 |
Is compliant with IEC 60947-4-1 |
Is compliant with IEC 60947-4-1 |
| suitability for isolation |
Yes conforming to IEC 60947-1 |
Applies to IEC 60947-1 |
Applies to IEC 60947-1 |
| Power dissipation per pole |
8 W |
8W |
8W |
| Mechanical durability |
50000 cycles |
50000 times |
50000 times |
| electrical durability |
50000 cycles for AC-3 at 415 V In |
50000 cycles for AC-3 at 415 V In |
50000 cycles for AC-3 at 415 V In |
| rated duty |
Continuous conforming to IEC 60947-4-1 |
Continuous according to IEC 60947-4-1 |
Continuous according to IEC 60947-4-1 |
| tightening torque |
5 N.m – on screw clamp terminal |
5 Nm via screw-in terminals |
5 Nm via screw-in terminals |
| Width |
55 mm |
55 mm |
55 mm |
| Height |
132 mm |
132 mm |
132 mm |
| Depth |
136 mm |
136 mm |
136 mm |
| Net weight |
0.96 kg |
0.96kg |
0.96kg |
| colour |
Dark grey |
Dark gray |
Dark gray |
| Environment |
| Standards |
EN/IEC 60947-2 |
TM-D |
TM-D |
| EN/IEC 60947-4-1 |
EN/IEC 60947-4-1 |
EN/IEC 60947-4-1 |
| UL 60947-4-1 |
UL 60947-4-1 |
UL 60947-4-1 |
| CSA C22.2 No 60947-4-1 |
DIN 3852-Y |
DIN 3852-Y |
| Product certifications |
CCC |
CCC |
CCC |
| EAC |
UL |
UL |
| BV |
CSA |
CSA |
| LROS (Lloyds register of shipping) |
EAC |
EAC |
| DNV-GL |
ATEX |
ATEX |
| ABS |
LROS (Lloyds register of shipping) |
LROS (Lloyds register of shipping) |
| UL |
BV |
BV |
| CSA |
ABS |
ABS |
| UKCA |
DNV-GL |
DNV-GL |
| ATEX |
UKCA |
UKCA |
| IK degree of protection |
IK09 enclosure |
IK09 cabinet |
IK09 cabinet |
| IP degree of protection |
IP20 conforming to IEC 60529 |
IP20 complies with screwed |
IP20 complies with screwed |
| climatic withstand |
Conforming to IACS E10 |
Conforms to IACS E10 |
Conforms to IACS E10 |
| Ambient air temperature for storage |
-40…80 °C |
-40…80°C |
-40…80°C |
| fire resistance |
960 °C conforming to IEC 60695-2-11 |
960 °C conforming to IEC 60695-2-11 |
960 °C conforming to IEC 60695-2-11 |
| ambient air temperature for operation |
-20…60 °C |
-20…60°C |
-20…60°C |
| mechanical robustness |
Shocks: 15 Gn for 11 ms contactor open |
Shock: 15 gn (11ms) with contacts open |
Shock: 15 gn (11ms) with contacts open |
| Shocks: 30 Gn for 11 ms contactor closed |
Shock: 30 Gn for 11 ms with contacts closed |
Shock: 30 Gn for 11 ms with contacts closed |
| Vibrations: 4 Gn, 5…300 Hz |
Shock: 4 gn (5…300 Hz) |
Shock: 4 gn (5…300 Hz) |
| operating altitude |
3000 m |
3000m |
3000m |
| Packing Units |
| Unit Type of Package 1 |
PCE |
PCE |
PCE |
| Number of Units in Package 1 |
1 |
1 |
1 |
| Package 1 Height |
16.000 cm |
16.000 cm |
16.000 cm |
| Package 1 Width |
6.500 cm |
6.500 cm |
6.500 cm |
| Package 1 Length |
14.600 cm |
14.500 cm |
14.600 cm |
| Package 1 Weight |
983 g |
1.008 kg |
1.016kg |
| Unit Type of Package 2 |
P06 |
P06 |
P06 |
| Number of Units in Package 2 |
120 |
120 |
120 |
| Package 2 Height |
75.000 cm |
75.000 cm |
75.000 cm |
| Package 2 Width |
60.000 cm |
60.000 cm |
60.000 cm |
| Package 2 Length |
80.000 cm |
80.000 cm |
80.000 cm |
| Package 2 Weight |
133.960 kg |
136.960 kg |
134.920kg |
| Contractual warranty |
| Warranty |
18 months |
18 months |
18 months |