| Main |
| Part Number |
LC1K0910M7 |
| Product Series |
TeSys |
| product type |
Contactor |
| product name |
TeSys K |
| Applications |
Remote control |
| Application field of contactor |
Applied to AC loads with power factor greater than or equal to 0.95 |
| Applied to non-inductive or slightly inductive loads, resistance furnaces |
| Additional information |
| use category |
AC-4 |
| AC-3 |
| AC-1 |
| AC-3e |
| number of poles |
3P |
| power pole contact composition |
3 NO |
| Rated operating current [Ie] |
20 A 50 °C) at <= 440 V AC AC-1 for power circuit |
| 9 A at <= 440 V AC AC-3 for power circuit |
| 16 A at 70 °C) at 690 V AC AC- 1 for power circuit |
| 9 A at <= 440 V AC AC-3e for power circuit |
| Control loop characteristics |
AC at 50/60 Hz |
| Control circuit voltage |
220…230 V AC 50/60 Hz |
| Motor power (kW) |
2.2 kW at 220…230 V AC 50/60 Hz AC-3 |
| 4 kW at 380…415 V AC 50/60 Hz AC-3 |
| 4 kW at 440 V AC 50/60 Hz AC-3 |
| 4 kW at 480 V AC 50/60 Hz AC-3 |
| 4 kW at 500…600 V AC 50/60 Hz AC-3 |
| 4 kW at 660…690 V AC 50 /60 Hz AC-3 |
| 2.2 kW at 400 V AC 50/60 Hz AC-4 |
| 2.2 kW at 220…230 V AC 50/60 Hz AC-3e |
| 4 kW at 380…415 V AC 50/60 Hz AC-3e |
| 4 kW at 440 V AC 50/60 Hz AC-3e |
| 4 kW at 480 V AC 50/60 Hz AC-3e |
| 4 kW at 500…600 V AC 50/60 Hz AC-3e |
| 4 kW at 660…690 V AC 50/60 Hz AC-3e |
| Auxiliary contact type |
1 NO |
| Overvoltage category |
III |
| Conventional thermal current [Ith] |
20 A at <50 °C for power circuits |
| 10 A at <50 °C for signal circuits |
| Rated making capacity [Irms] |
110 A AC for power circuits according to NF C 63-110 |
| 110 A AC for power circuits according to IEC 60947 |
| 110 A AC for signal circuits according to IEC 60947 |
| Rated breaking capacity |
110 A at 415 V conforming to IEC 60947 |
| 110 A at 440 V conforming to IEC 60947 |
| 80 A at 500 V conforming to IEC 60947 |
| 110 A at 220…230 V conforming to IEC 60947 |
| 110 A at 380 …400 V conforming to IEC 60947 |
| 70 A at 660…690 V conforming to IEC 60947 |
| Fuses for use with relays |
25 A gG at <= 440 V for power circuits |
| 25 A aM for power circuits |
| 10 A gG for signal circuits according to IEC 60947 |
| 10 A gG for signal circuits according to VDE 0660 |
| average impedance |
3 mΩ – Ith 20 A 50 Hz for power circuits |
| Insulation resistance |
> 10 MΩ for signal loops |
| (~50Hz pickup) power consumption (VA) |
30VA 20°C) |
| (~50Hz hold) power consumption (VA) |
4.5VA 20°C) |
| heat dissipation |
1.3W |
| Control voltage limit |
Operating: 0.85…1.1 Uc 50 °C) |
| Release: 0.2…0.75 Uc 50 °C) |
| operating frequency |
3600 times/hour |
| Auxiliary contact type |
Type Momentary 1 NO |
| Signal loop frequency |
≤ 400Hz |
| Minimum switching current [Imin] |
5 mA for signal loop |
| Minimum switching voltage |
17 V for signal return |
| action time |
10…20 ms coil discharging and NO opening |
| 10…20 ms coil energizing and NO contact closing |
| Safety and reliability level |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 |
| B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
| non-overlapping gap |
0.5 mm |
| Shock and vibration resistance |
Shock resistance in X direction, contacts closed: 10 gn (11ms) conforming to IEC 60068-2-27 |
| Shock resistance in Y direction, contacts closed: 15 gn (11ms) conforming to IEC 60068-2 -27 |
| Shock resistance in the direction of the Z axis, with contacts closed: 15 gn (11ms) conforming to IEC 60068-2-27 |
| Shock resistance in the direction of the X axis, contacts open: 6 gn (11ms) conforming to IEC 60068 -2-27 |
| Shock resistance in Y-axis direction, contact open state: 10 gn (11ms) conforming to IEC 60068-2-27 |
| Shock resistance in Z-axis direction, contact open state: 10 gn (11ms) conforming IEC 60068-2-27 |
| shock resistance with contacts closed: 4 gn (5…300 Hz) conforming to IEC 60068-2-6 |
| shock resistance with contacts open: 2 gn (5…300 Hz) conforming to IEC 60068 -2-6 |
| environment |
| certified product |
CSA |
| UL |
| UKCA |
| Protective measures |
TC conforming to IEC 60068 |
| TC conforming to DIN 50016 |
| working altitude |
2000 meters without |
| flame retardant |
V1 Conforms to UL 94 |
| requirements2 Conforms to NF F 16-101 |
| requirements2 Conforms to NF F 16-102 |
| packaging unit |
| Unit Type of Package 1 |
PCE |
| Number of Units in Package 1 |
1 |
| Package 1 Height |
5cm |
| Package 1 Width |
6cm |
| Package 1 Length |
6.5cm |
| Package 1 Weight |
178g |
| Unit Type of Package 2 |
S02 |
| Number of Units in Package 2 |
50 |
| Package 2 Height |
15cm |
| Package 2 Width |
30cm |
| Package 2 Length |
40cm |
| Package 2 Weight |
9.149 kg |
| Unit Type of Package 3 |
P06 |
| Number of Units in Package 3 |
800 |
| Package 3 Height |
75cm |
| Package 3 Width |
80cm |
| Package 3 Length |
60cm |
| Package 3 Weight |
154.384 kg |
| contract warranty |
| Warranty |
18 months |