$ 104.65
product brand name | SIRIUS |
product designation | timing relay |
design of the product | slow-operating |
product type designation | 3RP25 |
General technical data | |
product component | |
● relay output | Yes |
● semi-conductor output | No |
product extension required remote control | No |
product extension optional remote control | No |
power loss [W] maximum | 2 W |
insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value |
300 V |
test voltage for isolation test | 2.5 kV |
degree of pollution | 3 |
surge voltage resistance rated value | 4 000 V |
shock resistance according to IEC 60068-2-27 | 11g / 15 ms |
vibration resistance according to IEC 60068-2-6 | 10 … 55 Hz / 0.35 mm |
mechanical service life (operating cycles) typical | 10 000 000 |
electrical endurance (operating cycles) at AC-15 at 230 V typical |
100 000 |
adjustable time | 0.05 s … 100 h |
relative setting accuracy relating to full-scale value | 5 %; +/- |
thermal current | 5 A |
recovery time | 250 ms |
reference code according to IEC 81346-2 | K |
relative repeat accuracy | 1 %; +/- |
influence of the surrounding temperature | 1% in the whole temperature range to the set runtime |
power supply influence | 1% in the whole voltage range to the set runtime |
Substance Prohibitance (Date) | 09/12/2014 |
SVHC substance name | Lead monoxide (lead oxide) – 1317-36-8 |
Weight | 0.135 kg |
Control circuit/ Control | |
type of voltage of the control supply voltage | AC/DC |
control supply voltage 1 at AC | |
● at 50 Hz | 12 … 240 V |
● at 60 Hz | 12 … 240 V |
control supply voltage frequency 1 | 50 … 60 Hz |
control supply voltage 1 at DC | 12 … 240 V |
operating range factor control supply voltage rated value at DC |
|
● initial value | 0.8 |
● full-scale value | 1.1 |
operating range factor control supply voltage rated value at AC at 50 Hz |
|
● initial value | 0.8 |
● full-scale value | 1.1 |
operating range factor control supply voltage rated value at AC at 60 Hz |
|
● initial value | 0.8 |
● full-scale value | 1.1 |
inrush current peak | |
● at 24 V | 0.4 A |
● at 240 V | 5 A |
duration of inrush current peak | |
● at 24 V | 0.3 ms |
● at 240 V | 0.5 ms |
Switching Function | |
switching function | |
● ON-delay | Yes |
● ON-delay/instantaneous contact | No |
● passing make contact | No |
● passing make contact/instantaneous contact | No |
● OFF delay | No |
switching function | |
● flashing symmetrically with interval start/instantaneous | No |
● flashing symmetrically with interval start | No |
● flashing symmetrically with pulse start/instantaneous | No |
● flashing symmetrically with pulse start | No |
● flashing asymmetrically with interval start | No |
● flashing asymmetrically with pulse start | No |
switching function | |
● star-delta circuit with delay time | No |
● star-delta circuit | No |
switching function with control signal | |
● additive ON-delay | No |
● passing break contact | No |
● passing break contact/instantaneous | No |
● OFF delay | No |
● OFF delay/instantaneous | No |
● pulse delayed | No |
● pulse delayed/instantaneous | No |
● pulse-shaping | No |
● pulse-shaping/instantaneous | No |
● additive ON-delay/instantaneous | No |
● ON-delay/OFF-delay/instantaneous | No |
● passing make contact | No |
● passing make contact/instantaneous contact | No |
switching function of interval relay with control signal | |
● retrotriggerable with deactivated control signal/instantaneous contact |
No |
● retrotriggerable with switched-on control signal | No |
● retrotriggerable with switched-on control signal/instantaneous contact |
No |
● retriggerable with deactivated control signal | No |
Short-circuit protection | |
design of the fuse link for short-circuit protection of the auxiliary switch required |
fuse gL/gG: 4 A |
Auxiliary circuit | |
material of switching contacts | AgSnO2 |
number of NC contacts | |
● delayed switching | 0 |
● instantaneous contact | 0 |
number of NO contacts | |
● delayed switching | 0 |
● instantaneous contact | 0 |
number of CO contacts | |
● delayed switching | 1 |
● instantaneous contact | 0 |
operational current of auxiliary contacts at AC-15 | |
● at 24 V | 3 A |
● at 250 V | 3 A |
operational current of auxiliary contacts at DC-13 | |
● at 24 V | 1 A |
● at 125 V | 0.2 A |
● at 250 V | 0.1 A |
operating frequency with 3RT2 contactor maximum | 5 000 1/h |
contact reliability of auxiliary contacts | one incorrect switching operation of 100 million switching operations (17 V, 5 mA) |
contact rating of auxiliary contacts according to UL | R300 / B300 |
switching capacity current with inductive load | 0.01 … 3 A |
Inputs/ Outputs | |
product function | |
● at the relay outputs switchover delayed/without delay | No |
● non-volatile | No |
Electromagnetic compatibility | |
EMC emitted interference according to IEC 61812-1 | ambience A (industrial sector) |
EMC immunity according to IEC 61812-1 | corresponds to degree of severity 3 |
conducted interference | |
● due to burst according to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
● due to conductor-conductor surge according to IEC 61000-4-5 |
1 kV |
field-based interference according to IEC 61000-4-3 | 10 V/m |
electrostatic discharge according to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
Safety related data | |
category according to EN 954-1 | none |
Electrical Safety | |
protection class IP on the front according to IEC 60529 | IP20 |
type of insulation | Basic insulation |
Connections/ Terminals | |
product component removable terminal for auxiliary and control circuit |
Yes |
type of electrical connection for auxiliary and control circuit | screw-type terminals |
type of connectable conductor cross-sections | |
● solid | 1x (0.5 … 4.0 mm²), 2x (0.5 … 2.5 mm²) |
● finely stranded with core end processing | 1x (0.5 … 4 mm²), 2x (0.5 … 1.5 mm²) |
● for AWG cables solid | 1x (20 … 12), 2x (20 … 14) |
● for AWG cables stranded | 1x (20 … 12), 2x (20 … 14) |
connectable conductor cross-section | |
● solid | 0.5 … 4 mm² |
● finely stranded with core end processing | 0.5 … 4 mm² |
AWG number as coded connectable conductor cross section |
|
● solid | 20 … 12 |
● stranded | 20 … 14 |
tightening torque | 0.6 … 0.8 N·m |
design of the thread of the connection screw | M3 |
Installation/ mounting/ dimensions | |
mounting position | any |
fastening method | screw and snap-on mounting onto 35 mm DIN rail |
height | 100 mm |
width | 17.5 mm |
depth | 90 mm |
required spacing | |
● with side-by-side mounting | |
— forwards | 0 mm |
— backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
● for grounded parts | |
— forwards | 0 mm |
— backwards | 0 mm |
— upwards | 0 mm |
— at the side | 0 mm |
— downwards | 0 mm |
● for live parts | |
— forwards | 0 mm |
— backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
Ambient conditions | |
installation altitude at height above sea level maximum | 2 000 m |
ambient temperature | |
● during operation | -25 … +60 °C |
● during storage | -40 … +85 °C |
● during transport | -40 … +85 °CTiming relay, electronic on-delay 1 change-over contact, 7 time ranges 0.05 s…100 h 12-240 V AC/DC at 50/60 Hz AC with LED, screw terminal |
relative humidity during operation | 10 … 95 % |
Weight | 0.135 kg |
---|---|
Dimensions | 3.6 × 10.9 × 12.6 cm |