Part Number: 6026136
Non-contact safety switches: UE410-MU3T5
OEM Spec Ref
| Module | Main module | 
| Configuration method | Via rotary switch | 
| Safety integrity level | SIL3 (IEC 61508) | 
| Category | Category 4 (EN ISO 13849) | 
| Performance level | PL e (EN ISO 13849) | 
| PFHD (mean probability of a dangerous failure per hour) | 2.5 x 10-9 (EN ISO 13849) | 
| TM (mission time) | 20 years (EN ISO 13849) | 
| Restart interlock | Manual / automatic (configurable) | 
| External device monitoring (EDM) | ✔ | 
| AND operation | ✔ | 
| OR operation | ✔ | 
| Bypass | ✔ | 
| Differentiation between man and material (muting) | ✔ | 
| Inputs | 4 safety inputs 4 switching inputs | 
| Number of muting sensors | 0 / 2 | 
| Outputs | 4 safety outputs 2 test outputs | 
| Delay time (outputs Q3/Q4) | 0 s … 5 s | 
| Connection type | Plug-in screw-type terminals | 
| Display elements | LEDs | 
| Protection class | III (EN 61140) | 
| Type of voltage supply | PELV or SELV 1) | 
| Supply voltage VS | 24 V DC (19.2 V DC … 30 V DC) | 
| Residual ripple | ≤ 10 % | 
| Power consumption | ≤ 3 W (DC) | 
| Switch-on time | ≤ 60 s | 
| Internal power consumption | ≤ 3 W (DC) | 
1) The current of the power supply that powers the main unit must be limited to a maximum of 4 A, either through the power supply itself or a fuse.
Mechanical data
| Dimensions (W x H x D) | 22.5 mm x 96.5 mm x 120.8 mm | 
| Weight | + 180 g | 
Ambient data
| 
 | |||||||
| Ambient operating temperature | –25 °C … +55 °C | ||||||
| Storage temperature | –25 °C … +70 °C | ||||||
| Air humidity | ≤ 95 %, Non-condensing | ||||||
| Climate conditions according to | EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) | ||||||
| Electromagnetic compatibility (EMC) | Class A (EN 61000-6-2, EN 55011) | ||||||
| Vibration resistance | 5 g RMS, 5 Hz … 500 Hz (EN 60068-2-64) | ||||||
| Weight | 0.226 kg | 
|---|---|