Part Number: 6032672
Non-contact safety switches: UE410-XU4T5
OEM Spec Ref
| Module | I/O module |
| Configuration method | Via rotary switch |
| Safety integrity level | SIL3 (IEC 61508) |
| Category | Category 4 (EN ISO 13849) |
| Performance level | PL e (EN ISO 13849) |
| PFHD (mean probability of a dangerous failure per hour) | 2.5 x 10-9 (EN ISO 13849) |
| TM (mission time) | 20 years (EN ISO 13849) |
| Restart interlock | Manual / automatic (configurable) |
| External device monitoring (EDM) | ✔ |
| AND operation | ✔ |
| OR operation | ✔ |
| Bypass | ✔ |
| Differentiation between man and material (muting) | ✔ |
| Inputs | 4 safety inputs
4 switching inputs |
| Number of muting sensors | 0 / 2 |
| Outputs | 4 safety outputs
2 test outputs |
| Delay time (outputs Q3/Q4) | 0 s … 5 s |
| Connection type | Plug-in spring terminals |
| Display elements | LEDs |
| Protection class | III (EN 61140) |
| Voltage supply | Via A1, A2 |
| Type of voltage supply | PELV or SELV 1) |
| Supply voltage VS | 24 V DC (19.2 V DC … 30 V DC) |
| Residual ripple | ≤ 10 % |
| Power consumption | ≤ 3 W (DC) |
| Internal power consumption | ≤ 3 W (DC) |
Mechanical data
| Dimensions (W x H x D) | 22.5 mm x 96.5 mm x 120.8 mm |
| Weight | 180 g |
Ambient data
|
|||||||
| Ambient operating temperature | –25 °C … +55 °C | ||||||
| Storage temperature | –25 °C … +70 °C | ||||||
| Air humidity | 15 % … 95 %, Non-condensing | ||||||
| Climate conditions according to | EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) | ||||||
| Electromagnetic compatibility (EMC) | Class A (EN 61000-6-2, EN 55011) | ||||||
| Vibration resistance | 5 g RMS, 5 Hz … 500 Hz (EN 60068-2-64) | ||||||
| Weight | 0.228 kg |
|---|---|
| Dimensions | 14 × 3.5 × 17 cm |