Contact Us:
sales@axmatic.com

W12-3 – WL12-3P2431 Photoelectric Sensors – Small Photoelectric Sensors – SICK Sensor

$ 170.66

SKU N/A Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1041436
Photoelectric Sensor Model: WL12-3P2431
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 15.6 mm x 48.5 mm x 42 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m … 7 m 1)
Sensing range 0 m … 5 m 1)
Focus Approx. 1.5°
Type of light Visible red light
Light source LED 2)
Light spot size (distance) Ø 100 mm (3 m)
Angle of dispersion Approx. 1.5°
Wave length 640 nm
Adjustment Potentiometer, 5 turns
  • 1) Reflector PL80A.
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA 3)
Switching output PNP
Output function Complementary
Switching mode Light/dark switching
Signal voltage PNP HIGH/LOW > Uv – 2,5 V / ca. 0 V
Output current Imax. ≤ 100 mA
Response time ≤ 330 µs 4)
Switching frequency 1,500 Hz 5)
Connection type Male connector M12, 4-pin
Circuit protection 6)

7)

8)

Protection class III
Weight 120 g
Polarisation filter
Housing material Metal
Optics material Plastic, PMMA
Enclosure rating IP66

IP67

IP69K

Items supplied 2 x clamps BEF-KH-W12, incl. screws
Ambient operating temperature –40 °C … +60 °C
Ambient temperature, storage –40 °C … +75 °C
UL File No. NRKH.E181493 & NRKH7.E181493
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) C = interference suppression.
  • 8) D = outputs overcurrent and short-circuit protected.

Additional information

Related Products

IDS_camera_UI-5242SE Rev
SICK_sensor_Distance sensor_DME5000_DME5000-212
Omron_Safety Relay Units_G9SE-221-T05 DC24
Festo_Pressure valves_LRL-1-4-QS-10_153518
SIEMENS_SIMATIC-ET 200S_Digital Output Electronic Modules
SCHNEIDER_TeSys Deca Three-Pole Contactor,65A,220V,50-60Hz
Select your currency