SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1123755
Photoelectric Sensor Model: WTV4FE-8416A120A00
OEM Spec Ref
Functional principle | Photoelectric proximity sensor | ||||||||||||||
Functional principle detail | Background suppression, V-optics | ||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
|
|||||||||||||||
Special features | Pin2 pre-setting (MF): not active | ||||||||||||||
Special applications | Detecting transparent objects |
MTTFD | 661 years |
DCavg | 0 % |
TM (mission time) | 20 years (EN ISO 13849, rate of use: 60 %) |
IO-Link | ✔ , IO-Link V1.1 |
Data transmission rate | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure | Bit 0 = switching signal QL1 |
Bit 1 = switching signal QL2 | |
Bit 2 … 15 = Current receiver level (live) | |
VendorID | 26 |
DeviceID HEX | 0x8002EA |
DeviceID DEC | 8389354 |
Compatible master port type | A |
SIO mode support | Yes |
Supply voltage UB | 10 V DC … 30 V DC 1) | ||||||||||||||||||||||||||
Ripple | ≤ 5 Vpp | ||||||||||||||||||||||||||
Usage category | DC-12 (According to EN 60947-5-2)
DC-13 (According to EN 60947-5-2) |
||||||||||||||||||||||||||
Current consumption | ≤ 25 mA, without load. At UB = 24 V | ||||||||||||||||||||||||||
Protection class | III | ||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
|
1) Limit values.
2) Signal transit time with resistive load in switching mode.
3) With light/dark ratio 1:1.
4) This switching output must not be connected to another output.
Housing | Rectangular | ||||||||||
Design detail | Flat | ||||||||||
Dimensions (W x H x D) | 16 mm x 40.1 mm x 12.1 mm | ||||||||||
Connection | Cable with M12 male connector, 4-pin, 182 mm | ||||||||||
|
|||||||||||
|
|||||||||||
Weight | Approx. 30 g | ||||||||||
Maximum tightening torque of the fixing screws | 0.4 Nm |
Enclosure rating | IP66 (EN 60529)
IP67 (EN 60529) |
Ambient operating temperature | –40 °C … +60 °C |
Ambient temperature, storage | –40 °C … +75 °C |
Typ. Ambient light immunity | Artificial light: ≤ 50,000 lx
Sunlight: ≤ 50,000 lx |
Shock resistance | 30 g, 11 ms (3 positive and 3 negative shocks along X, Y, Z axes, 18 total shocks (EN60068-2-27)) |
Vibration resistance | 10 Hz … 1,000 Hz (Amplitude 1 mm, 3 x 30 min (EN60068-2-6)) |
Air humidity | 35 % … 95 %, relative humidity (no condensation) |
Electromagnetic compatibility (EMC) | EN 60947-5-2 |
Resistance to cleaning agent | ECOLAB |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
Weight | 0.051 kg |
---|---|
Dimensions | 1.6 × 4.01 × 1.21 cm |
Axmatic Sdn Bhd
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang