| Width | 151 mm | 
|---|---|
| Height | 304 mm | 
| Depth | 120 mm | 
| Installation distance right/left | 20 mm / 20 mm | 
| Installation distance top/bottom | 50 mm / 100 mm | 
| Degree of protection | IP67 | 
|---|---|
| Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 | 
| Ambient temperature (operation) | -25 °C … 85 °C (Derating >60°C: 2.5 %/K) | 
| Ambient temperature (start-up type tested) | -40 °C | 
| Ambient temperature (storage/transport) | -40 °C … 85 °C | 
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) | 
| Climatic class | 3K3 (in acc. with EN 60721) | 
| Degree of pollution | 4 | 
| Installation height | ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) | 
| Nominal input voltage range | 100 V AC … 240 V AC | 
|---|---|
| 110 V DC … 250 V DC | |
| Input voltage range | 100 V AC … 240 V AC 10 % | 
| 110 V DC … 250 V DC 10 % | |
| Dielectric strength maximum | ≤ 300 V AC 15 s | 
| AC frequency range | 50 Hz … 60 Hz | 
| Discharge current to PE | < 3.5 mA | 
| Current consumption | 5.6 A (100 V AC) | 
| 2.4 A (240 V AC) | |
| Nominal power consumption | 36.8 W | 
| Inrush current | typ. 20 A (at 25 °C) | 
| Mains buffering time | typ. 10 ms (120 V AC) | 
| typ. 15 ms (230 V AC) | |
| Input fuse | 10 A (internal (device protection)) | 
| Recommended breaker for input protection | 10 A … 16 A (Characteristics B, C, D, K) | 
| Type of protection | Transient surge protection | 
| Protective circuit/component | Varistor | 
| Nominal output voltage | 24 V DC ±1 % | 
|---|---|
| Nominal output current (IN) | 20 A | 
| Dynamic Boost (IDyn.Boost) | 30 A (5 s) | 
| Derating | > 60 °C … 70 °C (2.5%/K) | 
| Protection against overvoltage at the output (OVP) | ≤ 30 V DC | 
| Control deviation | < 1 % (change in load, static 10 % … 90 %) | 
| < 3 % (Dynamic load change 10 % … 90 %, 10 Hz) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | ≤ 30 mVPP | 
| Output power | 480 W | 
| Typical response time | < 1 s | 
| Maximum power dissipation in no-load condition | < 3 W (120 V AC) | 
| < 2.5 W (230 V AC) | |
| Power loss nominal load max. | < 48 W (120 V AC) | 
| < 36 W (230 V AC) | 
| Article Number | 1039830 | 
|---|---|
| Net weight | 3.7 kg | 
| Efficiency | 91 % (100 V AC) | 
| 93 % (230 V AC) | |
| MTBF (IEC 61709, SN 29500) | > 1400000 h (25 °C) | 
| > 800000 h (40 °C) | |
| > 400000 h (60 °C) | |
| Insulation voltage input/output | 4 kV AC (type test) | 
| 1.5 kV AC (routine test) | |
| Degree of protection | IP67 | 
| Protection class | I | 
| Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 | 
| Assembly instructions | Alignable: 20 mm horizontally, 50 mm vertically above, 100 mm vertically below | 
| Connection method | Circular connector | 
|---|---|
| Type of locking | M12 screw locking | 
| Coding | S-coded | 
| Number of positions | 3 | 
| Connection method | Circular connector | 
|---|---|
| Type of locking | M17 standard and SPEEDCON locking | 
| Coding | N-coded | 
| Number of positions | 4 | 
| Connection method | Circular connector | 
|---|---|
| Type of locking | SPEEDCON M12 | 
| Coding | A-coded | 
| Number of positions | 5 | 
| Standard – Electrical safety | IEC 61010-2-201 (SELV) | 
|---|---|
| Standard – Safety extra-low voltage | EN 60204-1 (PELV) | 
| Standard – Safe isolation | DIN VDE 0100-410 | 
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 | 
| Overvoltage category EN 61010-1 | III (≤ 2000 m) | 
| II (≤ 4000 m) | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
|---|---|
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | 
| Conducted noise emission | EN 55016 | 
| EN 61000-6-3 (Class B) | |
| Noise emission | EN 55016 | 
| EN 61000-6-3 (Class B) | |
| Flicker | EN 61000-3-3 | 
| Electrostatic discharge | EN 61000-4-2 | 
| Contact discharge | 6 kV (Test Level 4) | 
| Discharge in air | 8 kV (Test Level 4) | 
| Electromagnetic HF field | EN 61000-4-3 | 
| Frequency range | 80 MHz … 1 GHz | 
| Test field strength | 10 V/m (Test Level 3) | 
| Frequency range | 1 GHz … 2 GHz | 
| Test field strength | 10 V/m (Test Level 3) | 
| Frequency range | 2 GHz … 3 GHz | 
| Test field strength | 10 V/m (Test Level 3) | 
| Comments | Criterion A | 
| Fast transients (burst) | EN 61000-4-4 | 
| Input | 4 kV (Test Level 4 – asymmetrical) | 
| Output | 2 kV (Test Level 3 – asymmetrical) | 
| Signal | 2 kV (Test Level 2 – asymmetrical) | 
| Comments | Criterion A | 
| Surge voltage load (surge) | EN 61000-4-5 | 
| Input | 3 kV (Test Level 3 – symmetrical) | 
| 4 kV (Test Level 4 – asymmetrical) | |
| Output | 1 kV (Test Level 2 – symmetrical) | 
| 2 kV (Test Level 1 – asymmetrical) | |
| Signal | 1 kV (Test Level 2 – asymmetrical) | 
| Comments | Criterion B | 
| Conducted interference | EN 61000-4-6 | 
| Frequency range | 0.15 MHz … 80 MHz | 
| Voltage | 10 V (Test Level 3) | 
| Comments | Criterion A | 
| Voltage dips | EN 61000-4-11 | 
| Voltage | 230 V AC | 
| Frequency | 50 Hz | 
| Voltage dip | 70 % | 
| Number of periods | 25 periods | 
| Additional text | Test Level 2 | 
| Comments | Criterion A | 
| Voltage dip | 40 % | 
| Number of periods | 10 periods | 
| Additional text | Test Level 2 | 
| Comments | Criterion B | 
| Voltage dip | 0 % | 
| Number of periods | 1 period | 
| Additional text | Test Level 2 | 
| Comments | Criterion B | 
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
| Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. | 
| REACh SVHC | Lead 7439-92-1 | 
|---|