Input Data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Signal: Repeater power supply operation | |
Description of the input | Repeater power supply operation |
Number of inputs | 1 |
Current input signal | 4 mA … 20 mA |
Transmitter supply voltage | > 21.5 V (20 mA) |
> 21 V (23 mA) | |
Underload/overload signal range | 0 mA … 24 mA (Extended transmission range for diagnostics) |
[/fusion_table]
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Signal: Signal conditioner operation | |
Description of the input | Signal conditioner operation |
Current input signal | 0 mA … 20 mA |
4 mA … 20 mA | |
Voltage drop | < 3.9 V (in input isolating amplifier operation) |
Underload/overload signal range | 0 mA … 24 mA (Extended transmission range for diagnostics) |
[/fusion_table]
Output Data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Signal: Repeater power supply operation | |
Output description | Repeater power supply operation |
Number of outputs | 2 |
Current output signal | 4 mA … 20 mA (active) |
0 mA … 20 mA | |
Load/output load current output | < 450 Ω (20 mA) |
< 380 Ω (23 mA) | |
Output ripple | < 20 mVrms |
Output behavior in the event of an error | 0 mA (Cable break in the input) |
≥ 23 mA (Cable short-circuit in the input) | |
Underload/overload signal range | 0 mA … 24 mA (Extended transmission range for diagnostics) |
[/fusion_table]
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Signal: Signal conditioner operation | |
Output description | Signal conditioner operation |
Current output signal | 0 mA … 20 mA (active) |
4 mA … 20 mA (active) | |
Load/output load current output | < 450 Ω (20 mA) |
< 380 Ω (23 mA) | |
Output ripple | < 20 mVrms |
Output behavior in the event of an error | 0 mA (Cable break in the input) |
0 mA (Cable short-circuit in the input) | |
Underload/overload signal range | 0 mA … 24 mA (Extended transmission range for diagnostics) |
[/fusion_table]
Connection Data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Connection method | Push-in connection |
Stripping length | 8 mm |
Conductor cross section solid | 0.2 mm² … 1.5 mm² |
Conductor cross section flexible | 0.2 mm² … 1.5 mm² |
Conductor cross section AWG | 24 … 16 |
[/fusion_table]
Dimensions
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Width | 12.5 mm |
Height | 116 mm |
Depth | 113.7 mm |
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
[/fusion_table]
Commercial Data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Item number | 2924838 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product Key | CK1111 |
Catalog Page | Page 121 (C-5-2019) |
GTIN | 4046356572057 |
Weight per Piece (including packing) | 238.2 g |
Weight per Piece (excluding packing) | 153 g |
Customs tariff number | 85437090 |
Country of origin | DE |
[/fusion_table]
Ambient conditions
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Degree of protection | IP20 (not assessed by UL) |
Ambient temperature (operation) | -40 °C … 70 °C (Any mounting position) |
Ambient temperature (storage/transport) | -40 °C … 80 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 10 % … 95 % (non-condensing) |
[/fusion_table]
Weight | 0.153 kg |
---|---|
Dimensions | 11.37 × 1.25 × 11.6 cm |