$ 154.10
Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Item number | 2864082 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | DK1136 |
Catalog page | Page 110 (C-7-2015) |
GTIN | 4046356046435 |
Weight per piece (including packing) | 108.3 g |
Weight per piece (excluding packing) | 108.3 g |
Customs tariff number | 85437090 |
Country of origin | DE |
Utilization restriction | |
EMC note | EMC: class A product, see manufacturer’s declaration in the download area |
Product type | Frequency value transformer |
Product family | MINI Analog |
No. of channels | 1 |
Configuration | DIP switches |
Insulation characteristics | |
Overvoltage category | II |
Pollution degree | 2 |
Functionality | |
Configuration | DIP switches |
Electrical isolation between input and output | yes |
Step response (0–99%) | < 15 ms (+ (1/f) smallest filter) |
< 1 s (+ (1/f) largest filter) | |
Maximum temperature coefficient | < 0.02 %/K |
Temperature coefficient, typical | < 0.02 %/K |
Maximum transmission error | ≤ 0.1 % (> 7 kHz ≤ 0.2 %) |
Electrical isolation Input/output/power supply | |
Rated insulation voltage | 30 V AC |
50 V DC | |
Test voltage | 1.5 kV AC (50 Hz, 60 s) |
Insulation | Basic insulation in accordance with IEC/EN 61010 |
Supply | |
Nominal supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC … 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Max. current consumption | < 10 mA (at 24 V DC) |
Power consumption | < 200 mW |
Signal: Voltage/current | |
Number of inputs | 1 |
Configurable/programmable | Yes |
Voltage input signal | 0 V … 5 V |
1 V … 5 V | |
0 V … 10 V | |
2 V … 10 V | |
Max. voltage input signal | 30 V DC |
Current input signal | 0 mA … 20 mA |
4 mA … 20 mA | |
0 mA … 10 mA | |
2 mA … 10 mA | |
Max. current input signal | 100 mA |
Input resistance of voltage input | approx. 110 kΩ |
Input resistance current input | approx. 50 Ω |
Behavior in the event of an error | Alarm in the form of a red LED |
Frequency: Frequency | |
Frequency output | 0 Hz … 10 kHz |
0 Hz … 5 kHz | |
0 Hz … 2.5 kHz | |
0 Hz … 1 kHz | |
0 Hz … 500 Hz | |
0 Hz … 250 Hz | |
0 Hz … 100 Hz | |
0 Hz … 50 Hz | |
Load min. | 4 mA ≤ (UL / RL) ≤ 20 mA |
Output signal PWM | 7.8 kHz (10 bit) |
3.9 kHz (10 bit) | |
1.9 kHz (12 bit) | |
977 Hz (12 bit) | |
488 Hz (14 bit) | |
244 Hz (14 bit) | |
122 Hz (16 bit) | |
61 Hz (16 bit) | |
Load min. | 12 mA ≤ (UL/RL) ≤ 20 mA |
Load current maximum | 20 mA |
Maximum switching voltage | 30 V |
Overrange/underrange | can be set (via DIP switch) |
Protective circuit | Short-circuit protection, polarity reversal protection |
Signal | |
Number of outputs | 1 |
Connection method | Screw connection |
Stripping length | 12 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross section AWG | 26 … 12 |
Width | 6.2 mm |
Height | 93.1 mm |
Depth | 101.2 mm |
Color | green (RAL 6021) |
Housing material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 2 |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -20 °C … 65 °C |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % … 95 % (non-condensing) |
CE | |
Certificate | CE-compliant |
UKCA | |
Certificate | UKCA-compliant |
UL, USA/Canada | |
Identification | UL 508 Recognized |
Class I, Div. 2, Groups A, B, C, D T4 | |
Shipbuilding approval | |
Certificate | DNV GL TAA000020N |
Shipbuilding data | |
Temperature | B |
Humidity | B |
Vibration | B |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Electromagnetic compatibility | Conformance with EMC directive |
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Noise emission | |
Standards/regulations | EN 61000-6-4 |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field | |
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 2 % |
Fast transients (burst) | |
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 2 % |
Surge current load (surge) | |
Standards/regulations | EN 61000-4-5 |
Surge current load (surge) | |
Comments | Criterion B |
Conducted interference | |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 2 % |
Mounting type | DIN rail mounting |
Mounting position | any |
Weight | 0.1083 kg |
---|---|
Dimensions | 10.12 × 0.62 × 9.31 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,