Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.

Input Data

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Nominal input voltage UN 24 V DC
Input voltage range in reference to UN 0.8 … 1.2
Input voltage range 19.2 V DC … 28.8 V DC
Switching threshold “0” signal, voltage ≤ 10 V
Switching threshold “1” signal voltage ≥ 16 V
Typical input current at UN 7 mA
Typical response time 20 µs (at UN)
Typical turn-off time 300 µs (at UN)
Transmission frequency 300 Hz

[/fusion_table]

Output Data

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Contact type 1 N/O contact
Design of digital output electronic
Output voltage range 3 V DC … 33 V DC
Limiting continuous current 3 A (see derating curve)
Maximum inrush current 15 A (10 ms)
Voltage drop at max. limiting continuous current ≤ 150 mV
Output circuit 2-conductor, floating
Protective circuit Reverse polarity protection
Surge protection

[/fusion_table]

Dimensions

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Width 5 mm
Height 28 mm
Depth 15 mm

[/fusion_table]

Commercial Data

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Item number 2966595
Packing unit 10 pc
Minimum order quantity 10 pc
Sales Key 08
Product Key CK61F2
Catalog Page Page 286 (C-5-2019)
GTIN 4017918130947
Weight per Piece (including packing) 5.26 g
Weight per Piece (excluding packing) 5.2 g
Customs tariff number 85364190
Country of origin HU

[/fusion_table]

Ambient conditions

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Degree of protection RT III
Ambient temperature (operation) -25 °C … 60 °C
Ambient temperature (storage/transport) -25 °C … 70 °C

[/fusion_table]

Weight 0.0052 kg
Dimensions 1.5 × 0.5 × 2.8 cm