$ 175.26
Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Item number | 2700578 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | DNA182 |
Catalog page | Page 252 (C-6-2019) |
GTIN | 4046356916400 |
Weight per piece (including packing) | 199.8 g |
Weight per piece (excluding packing) | 182.1 g |
Customs tariff number | 85364900 |
Country of origin | DE |
Note on application | |
Note on application | Only for industrial use |
Utilization restriction | |
CCCex note | Use in potentially explosive areas is not permitted in China |
Product type | Coupling relay |
Product family | PSRmini |
Application | Safe switch off |
High demand | |
Low demand | |
Ex | |
Control | 1-channel |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Insulation characteristics: Air clearances and creepage distances between the power circuits | |
Overvoltage category | III |
Degree of pollution | 2 |
Times | |
Typ. starting time with Us | < 100 ms (with Us when controlled via A1) |
Typical release time | < 35 ms (when controlled via A1) |
Recovery time | 500 ms |
Maximum power dissipation for nominal condition | 3.43 W (IL² = 36 A²) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits | |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | Safe isolation, 6 kV reinforced insulation from control circuit, start circuit, confirmation current path, signal output to the enabling current path; 4 kV/basic insulation between all current paths and housing |
Supply | |
Designation | A1/A2 |
Rated control circuit supply voltage US | 20.4 V DC … 26.4 V DC |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
Rated control supply current IS | typ. 50 mA |
Power consumption at US | typ. 1.2 W |
Inrush current | typ. 400 mA (Δt < 10 µs at Us) |
Filter time | max. 2 ms (at A1-A2; test pulse width) |
≥ 100 ms (at A1-A2; test pulse rate) | |
Protective circuit | Serial protection against polarity reversal; Suppressor diode 33 V |
Supply | |
Designation | 31/A2, TBUS |
Diagnostic supply voltage UD | 24 V DC -15 % / +10 % |
Input current at UD | 6 mA (at 31-A2 for UD; depending on load + 100 mA at M1 and 32) |
Inrush current at UD | typ. 2.5 A (Δt < 20 µs at UD) |
Protective circuit | Serial protection against polarity reversal; Suppressor diode 33 V |
Relay: Enabling current path (13/14 (13F/14)) | |
Output description | 2 N/O contacts in series, without delay, floating |
Number of outputs | 1 (safety-related) |
Contact switching type | 1 enabling current path |
Contact material | AgSnO2 |
Switching voltage | min. 12 V AC/DC |
max. 250 V AC/DC | |
Switching capacity | min. 60 mW |
Inrush current | min. 3 mA |
max. 6 A (N/O contact 13/14) | |
4 A (N/O contact 13F/14) | |
Switching capacity in accordance with IEC 60947-5-1 | 4 A (24 V (DC13); N/O contact 13/14) |
5 A (250 V (AC15); N/O contact 13/14) | |
4 A (250 V (AC15); N/O contact 13F/14) | |
Limiting continuous current | 6 A (13/14 for high-demand) |
4 A (13F/14 with high/low demand, 13/14 with low demand) | |
Sq. Total current | 36 A2 (13/14, see to derating) |
16 A2 (13F/14, see to derating) | |
Switching frequency | max. 0.1 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 6 A gL/gG (N/O contact 13/14) |
4 A gL/gG (for low-demand applications) | |
Relay: Confirmation current path (31/32) | |
Output description | 2 N/C contacts in series, without delay, not floating (reference ground: A2) |
Number of outputs | 1 (safety-related) |
Contact switching type | 1 confirmation current path |
Contact material | AgCuNi, + Au |
Switching voltage | min. 20.4 V DC |
max. 26.4 V DC | |
Switching capacity | min. 20 mW |
Inrush current | min. 1 mA |
max. 100 mA | |
Limiting continuous current | 100 mA |
Switching frequency | max. 0.1 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 150 mA Fast-blow |
Signal: M1 | |
Output description | PNP |
Number of outputs | 1 (non-safety-related) |
Voltage | approx. 22 V DC (UD – 2 V) |
Current | max. 100 mA |
Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
Short-circuit protection | no |
Output fuse | 150 mA fast blow |
Connection technology | |
pluggable | yes |
Conductor connection | |
Connection method | Push-in connection |
Conductor cross section rigid | 0.2 mm² … 1.5 mm² |
Conductor cross section flexible | 0.2 mm² … 1.5 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² … 1.5 mm² (only together with CRIMPFOX 6) |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² … 1.5 mm² (only together with CRIMPFOX 6) |
Conductor cross-section AWG | 24 … 16 |
Stripping length | 8 mm |
Status display | 1 x LED (green) |
Operating voltage display | 1 x LED (yellow) |
Error indication | 1 x LED (red) |
Width | 12.5 mm |
Height | 116.6 mm |
Depth | 114.5 mm |
Color (Housing) | yellow (RAL 1018) |
Housing material | PA |
Safety data | |
Stop category | 0 |
Safety data: EN 50156 | |
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 – High demand | |
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 – Low demand | |
Safety Integrity Level (SIL) | 3 |
Ambient conditions | |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient temperature (operation) | -40 °C … 70 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (operation) | 10 Hz … 150 Hz, 2g |
ATEX | |
Identification | II 3G Ex ec nC IIC T4 Gc |
Certificate | UL 22 ATEX 2912X |
IECEx | |
Identification | Ex ec nC IIC T4 Gc |
Certificate | IECEx UL 22.0037X |
UL, USA/Canada | |
Identification | cULus |
Certificate | E140324 |
UL Ex, USA / Canada | |
Identification | Class I, Zone 2, AEx ec nC IIC T4 / Ex ec nC IIC Gc T4 X |
Class I, Div. 2, Groups A, B, C, D, T4 | |
Certificate | E360692 |
CE | |
Identification | CE-compliant |
Environmental simulation test | |
Identification | G3 |
Certificate | ISA-S71.04 |
CCC / China-Ex | |
Identification | Ex ec nC IIC T4 Gc |
Certificate | 2022122304115695 |
DNV | |
Identification | C, EMC2 |
Certificate | 11253-14 HH |
Air clearances and creepage distances between the power circuits | |
Standards/regulations | EN 60664-1, EN 60079-7, EN 60079-15 |
Mounting type | DIN rail mounting |
Assembly note | See derating curve |
Mounting position | vertical, horizontal, with front of module upward |
Weight | 0.1998 kg |
---|---|
Dimensions | 11.45 × 1.25 × 11.66 cm |