Contact Us:
sales@inosaki.com

PSR-SCP- 24DC/FSP/1X1/1X2 – 2981978 – Phoenix Contact Safe Coupling Relays

$ 210.68

SKU Phoenix Contact 2981978 Category

Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.

Commercial Data

Item number 2981978
Packing unit 1 pc
Minimum order quantity 1 pc
Sales key DNA
Product key DNA161
Catalog page Page 254 (C-6-2019)
GTIN 4046356448352
Weight per piece (including packing) 160 g
Weight per piece (excluding packing) 155 g
Customs tariff number 85364190
Country of origin DE

Notes

Note on application
Note on application Only for industrial use

Product Properties

Product type Coupling relay
Product family PSRclassic
Application Safe switch off
High demand
Low demand
Control 1-channel
Mechanical service life 10x 106 cycles
Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Insulation characteristics: Air clearances and creepage distances between the power circuits
Overvoltage category III
Degree of pollution 2

Electrical Properties

Maximum power dissipation for nominal condition 2.4 W
Nominal operating mode 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage 250 V AC
Rated surge voltage/insulation Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (21/22), (13/14)

Input Data

General
Rated control circuit supply voltage US 24 V DC -15 % / +10 %
Power consumption at US typ. 1.32 W
Rated control supply current IS typ. 55 mA
Input voltage range 20.4 V DC … 26.4 V DC
Inrush current max. 100 mA
Filter time max. 5 ms (at A1 in the event of voltage dips at Us)
max. 2 ms (Test pulse width; high test pulse at A1/A2)
≥ 100 ms (Test pulse width; high test pulse at A1/A2)
Test pulse rate = 80 x Test pulse width
max. 5 ms (Test pulse width; low test pulse at A1/A2)
≥ 50 ms (Test pulse rate; low test pulse at A1/A2)
Test pulse rate = 15 x Test pulse width
Typ. starting time with Us 50 ms
Typical release time 50 ms
Recovery time 1 s
Maximum switching frequency 0.5 Hz
Protective circuit Surge protection; Suppressor diode, 33 V (A1 – A2)
Operating voltage display 1 x yellow LED

Output Data

Contact switching type 1 enabling current path
1 confirmation current path
Contact material AgCuNi, + 0.2 µm Au
Maximum switching voltage 250 V AC/DC (N/O contact / N/C contact, observe the load curve)
Minimum switching voltage 15 V AC/DC (N/O contact / N/C contact)
Limiting continuous current 5 A (N/O contact, pay attention to the derating)
100 mA (N/C contact)
Maximum inrush current 5 A (N/O contact)
100 mA (N/C contact)
Inrush current, minimum 5 mA (N/O contact / N/C contact)
Sq. Total current 25 A2 (observe derating)
Interrupting rating (ohmic load) max. 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W)
192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W)
162 W (60 V DC, τ = 0 ms, N/C contact: 6 W)
66 W (110 V DC, τ = 0 ms, N/C contact: 11 W)
60 W (220 V DC, τ = 0 ms, N/C contact: 22 W)
1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA)
Maximum interrupting rating (inductive load) 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W)
43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W)
41 W (60 V DC, τ = 40 ms, N/C contact: 6 W)
35 W (110 V DC, τ = 40 ms, N/C contact: 11 W)
48 W (220 V DC, τ = 40 ms, N/C contact: 22 W)
Switching capacity min. 75 mW
Switching capacity (3600/h cycles) 5 A (24 V (DC13))
5 A (230 V (AC15))
Output fuse 5 A T fuse (N/O contact)
150 mA Fast-blow (N/C contact)

Connection Data

Connection technology
pluggable yes
Conductor connection
Connection method Screw connection
Conductor cross section rigid 0.2 mm² … 2.5 mm²
Conductor cross section flexible 0.2 mm² … 2.5 mm²
Conductor cross-section AWG 24 … 12
Stripping length 7 mm
Screw thread M3

Dimension

Width 17.5 mm
Height 99 mm
Depth 114.5 mm

Material Specifications

Color (Housing) yellow (RAL 1018)
Housing material PA

Characteristics

Safety data
Stop category 0
Safety data: EN ISO 13849
Category 4 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%)
Performance level (PL) e (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%)
Safety data: EN 50156
Safety Integrity Level (SIL) 3
Safety data: IEC 61508 – High demand
Safety Integrity Level (SIL) 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% )
Safety data: IEC 61508 – Low demand
Safety Integrity Level (SIL) 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% )
Safety data: EN IEC 62061
Safety Integrity Level (SIL) 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% )

Environmental and real-life conditions 

Ambient conditions
Degree of protection IP20
Min. degree of protection of inst. location IP54
Ambient temperature (operation) -20 °C … 55 °C (observe derating)
Ambient temperature (storage/transport) -40 °C … 70 °C
Maximum altitude ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Shock 15g
Vibration (operation) 10 Hz … 150 Hz, 2g

Approvals

CE
Certificate CE-compliant

Standard And Regulations

Air clearances and creepage distances between the power circuits
Standards/regulations IEC 60664-1

Mounting

Mounting type DIN rail mounting
Mounting position any

Additional information

Weight 0.160 kg
Dimensions 11.45 × 1.75 × 9.9 cm

Related Products

SIEMENS_SIMATIC-ET 200pro_Connection module for the fail-safe electronic module_6ES7194-4DC00-0AA0
M6 -1
Festo_Directional control valves_VMPA2-M1H-MS-PI_571333
Festo_Directional control valves_VMPA14-M1HF-M-PI_578806
M3
Mitutoyo_Lever Indicators_513-424-10E