| Item number | 2986575 |
| Packing unit | 1 pc |
| Minimum order quantity | 1 pc |
| Product key | DNA161 |
| Catalog page | Page 255 (C-6-2019) |
| GTIN | 4046356553322 |
| Weight per piece (including packing) | 141.05 g |
| Weight per piece (excluding packing) | 136.3 g |
| Customs tariff number | 85364190 |
| Country of origin | DE |
| Note on application | |
| Note on application | Only for industrial use |
| Product type | Coupling relay |
| Product family | PSRclassic |
| Application | Safe switch off |
| High demand | |
| Low demand | |
| Control | 1-channel |
| Mechanical service life | 10x 106 cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Insulation characteristics: Air clearances and creepage distances between the power circuits | |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Maximum power dissipation for nominal condition | 2.4 W |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (31/32), (13/14, 23/24) |
Input Data
| General | |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Power consumption at US | typ. 1.32 W |
| Rated control supply current IS | typ. 55 mA |
| Input voltage range | 20.4 V DC … 26.4 V DC |
| Inrush current | max. 100 mA |
| Filter time | max. 5 ms (at A1 in the event of voltage dips at Us) |
| max. 2 ms (Test pulse width; high test pulse at A1/A2) | |
| ≥ 100 ms (Test pulse width; high test pulse at A1/A2) | |
| Test pulse rate = 80 x Test pulse width | |
| max. 5 ms (Test pulse width; low test pulse at A1/A2) | |
| ≥ 50 ms (Test pulse rate; low test pulse at A1/A2) | |
| Test pulse rate = 15 x Test pulse width | |
| Typ. starting time with Us | 50 ms |
| Typical release time | 50 ms |
| Recovery time | 1 s |
| Maximum switching frequency | 0.5 Hz |
| Protective circuit | Surge protection; Suppressor diode, 33 V (A1 – A2) |
| Operating voltage display | 1 x yellow LED |
| Contact switching type | 2 enabling current paths |
| 1 confirmation current path | |
| Contact material | AgCuNi, + 0.2 µm Au |
| Maximum switching voltage | 250 V AC/DC (N/O contact / N/C contact, observe the load curve) |
| Minimum switching voltage | 15 V AC/DC (N/O contact / N/C contact) |
| Limiting continuous current | 5 A (N/O contact, pay attention to the derating) |
| 100 mA (N/C contact) | |
| Maximum inrush current | 5 A (N/O contact) |
| 100 mA (N/C contact) | |
| Inrush current, minimum | 5 mA (N/O contact / N/C contact) |
| Sq. Total current | 50 A2 (observe derating) |
| Interrupting rating (ohmic load) max. | 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W) |
| 192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W) | |
| 162 W (60 V DC, τ = 0 ms, N/C contact: 6 W) | |
| 66 W (110 V DC, τ = 0 ms, N/C contact: 11 W) | |
| 60 W (220 V DC, τ = 0 ms, N/C contact: 22 W) | |
| 1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA) | |
| Maximum interrupting rating (inductive load) | 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W) |
| 43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W) | |
| 41 W (60 V DC, τ = 40 ms, N/C contact: 6 W) | |
| 35 W (110 V DC, τ = 40 ms, N/C contact: 11 W) | |
| 48 W (220 V DC, τ = 40 ms, N/C contact: 22 W) | |
| Switching capacity | min. 75 mW |
| Switching capacity (3600/h cycles) | 5 A (24 V (DC13)) |
| 5 A (230 V (AC15)) | |
| Output fuse | 10 A gL/gG (N/O contact) |
| 4 A gL/gG (for low-demand applications) | |
| 150 mA Fast-blow (N/C contact) |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² … 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
| Conductor cross-section AWG | 24 … 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Width | 17.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | PA |
| Safety data | |
| Stop category | 0 |
| Safety data: EN ISO 13849 | |
| Category | 1 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
| Performance level (PL) | c (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
| Safety data: EN 50156 | |
| Safety Integrity Level (SIL) | 2 |
| Safety data: IEC 61508 – High demand | |
| Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Safety data: IEC 61508 – Low demand | |
| Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 1 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C … 55 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C … 70 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz … 150 Hz, 2g |
| CE | |
| Certificate | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | IEC 60664-1 |
| Mounting type | DIN rail mounting |
| Mounting position | any |
| Weight | 0.14105 kg |
|---|---|
| Dimensions | 11.45 × 1.75 × 9.9 cm |