$ 154.10
Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Item number | 2986575 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | DNA161 |
Catalog page | Page 255 (C-6-2019) |
GTIN | 4046356553322 |
Weight per piece (including packing) | 141.05 g |
Weight per piece (excluding packing) | 136.3 g |
Customs tariff number | 85364190 |
Country of origin | DE |
Note on application | |
Note on application | Only for industrial use |
Product type | Coupling relay |
Product family | PSRclassic |
Application | Safe switch off |
High demand | |
Low demand | |
Control | 1-channel |
Mechanical service life | 10x 106 cycles |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Insulation characteristics: Air clearances and creepage distances between the power circuits | |
Overvoltage category | III |
Degree of pollution | 2 |
Maximum power dissipation for nominal condition | 2.4 W |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits | |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (31/32), (13/14, 23/24) |
Input Data
General | |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
Power consumption at US | typ. 1.32 W |
Rated control supply current IS | typ. 55 mA |
Input voltage range | 20.4 V DC … 26.4 V DC |
Inrush current | max. 100 mA |
Filter time | max. 5 ms (at A1 in the event of voltage dips at Us) |
max. 2 ms (Test pulse width; high test pulse at A1/A2) | |
≥ 100 ms (Test pulse width; high test pulse at A1/A2) | |
Test pulse rate = 80 x Test pulse width | |
max. 5 ms (Test pulse width; low test pulse at A1/A2) | |
≥ 50 ms (Test pulse rate; low test pulse at A1/A2) | |
Test pulse rate = 15 x Test pulse width | |
Typ. starting time with Us | 50 ms |
Typical release time | 50 ms |
Recovery time | 1 s |
Maximum switching frequency | 0.5 Hz |
Protective circuit | Surge protection; Suppressor diode, 33 V (A1 – A2) |
Operating voltage display | 1 x yellow LED |
Contact switching type | 2 enabling current paths |
1 confirmation current path | |
Contact material | AgCuNi, + 0.2 µm Au |
Maximum switching voltage | 250 V AC/DC (N/O contact / N/C contact, observe the load curve) |
Minimum switching voltage | 15 V AC/DC (N/O contact / N/C contact) |
Limiting continuous current | 5 A (N/O contact, pay attention to the derating) |
100 mA (N/C contact) | |
Maximum inrush current | 5 A (N/O contact) |
100 mA (N/C contact) | |
Inrush current, minimum | 5 mA (N/O contact / N/C contact) |
Sq. Total current | 50 A2 (observe derating) |
Interrupting rating (ohmic load) max. | 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W) |
192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W) | |
162 W (60 V DC, τ = 0 ms, N/C contact: 6 W) | |
66 W (110 V DC, τ = 0 ms, N/C contact: 11 W) | |
60 W (220 V DC, τ = 0 ms, N/C contact: 22 W) | |
1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA) | |
Maximum interrupting rating (inductive load) | 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W) |
43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W) | |
41 W (60 V DC, τ = 40 ms, N/C contact: 6 W) | |
35 W (110 V DC, τ = 40 ms, N/C contact: 11 W) | |
48 W (220 V DC, τ = 40 ms, N/C contact: 22 W) | |
Switching capacity | min. 75 mW |
Switching capacity (3600/h cycles) | 5 A (24 V (DC13)) |
5 A (230 V (AC15)) | |
Output fuse | 10 A gL/gG (N/O contact) |
4 A gL/gG (for low-demand applications) | |
150 mA Fast-blow (N/C contact) |
Connection technology | |
pluggable | yes |
Conductor connection | |
Connection method | Screw connection |
Conductor cross section rigid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross-section AWG | 24 … 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Width | 17.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Color (Housing) | yellow (RAL 1018) |
Housing material | PA |
Safety data | |
Stop category | 0 |
Safety data: EN ISO 13849 | |
Category | 1 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
Performance level (PL) | c (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
Safety data: EN 50156 | |
Safety Integrity Level (SIL) | 2 |
Safety data: IEC 61508 – High demand | |
Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Safety data: IEC 61508 – Low demand | |
Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Safety data: EN IEC 62061 | |
Safety Integrity Level (SIL) | 1 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Ambient conditions | |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient temperature (operation) | -20 °C … 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C … 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (operation) | 10 Hz … 150 Hz, 2g |
CE | |
Certificate | CE-compliant |
Air clearances and creepage distances between the power circuits | |
Standards/regulations | IEC 60664-1 |
Mounting type | DIN rail mounting |
Mounting position | any |
Weight | 0.14105 kg |
---|---|
Dimensions | 11.45 × 1.75 × 9.9 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)