Axmatic – Your Trusted Phoenix Contact Distributor
Axmatic proudly stands as one of the largest distributors of Phoenix Contact products, offering a comprehensive range of terminal blocks, interface modules, power supplies, and relays.
Series Models: PT Series, ST Series, TB Series, UT Series, and UK Series, PTV Series, UKH Series, Micro Series.
Discover industry-leading Phoenix Contact power supplies, such as:
Get Your Phoenix Contact Catalog Today
Need detailed product information? Contact us at sales@axmatic.com to request your Phoenix Contact catalog.
| Article Number | 2904607 | 
|---|---|
| Width | 45 mm | 
| Height | 106 mm | 
| Depth | 90 mm | 
| Installation distance right/left (active, passive) | 0 mm / 0 mm (POut ≤50 %) | 
| Installation distance right/left (passive) | 5 mm / 5 mm (POut ≥50% ) | 
| Installation distance right/left (active) | 15 mm / 15 mm (POut ≥50% ) | 
| Installation distance top/bottom (active, passive) | 30 mm / 30 mm (POut ≤50 %) | 
| Installation distance top/bottom (passive) | 30 mm / 30 mm (POut ≥50% ) | 
| Installation distance top/bottom (active) | 30 mm / 30 mm (POut ≥50% ) | 
| Degree of protection | IP20 | 
|---|---|
| Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 | 
| Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K) | 
| Ambient temperature (start-up type tested) | -40 °C | 
| Ambient temperature (storage/transport) | -40 °C … 85 °C | 
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) | 
| Climatic class | 3K3 (in acc. with EN 60721) | 
| Degree of pollution | 2 | 
| Installation height | ≤ 5000 m (> 2000 m, observe derating) | 
| Input voltage range | 100 V AC … 240 V AC -15 % … +10 % | 
|---|---|
| 110 V DC … 250 V DC -20 % … +40 % | |
| Dielectric strength maximum | 300 V AC 60 s | 
| Frequency range (fN) | 50 Hz … 60 Hz -10 % … +10 % | 
| Discharge current to PE | < 0.25 mA (264 V AC, 60 Hz) | 
| Current consumption | 1 A (100 V AC) | 
| 0.85 A (120 V AC) | |
| 0.46 A (230 V AC) | |
| 0.44 A (240 V AC) | |
| Nominal power consumption | 96.3 VA | 
| Inrush current | typ. 11.4 A (at 25 °C) | 
| Mains buffering time | typ. 48 ms (120 V AC) | 
| typ. 48 ms (230 V AC) | |
| Input fuse | 3.15 A (slow-blow, internal) | 
| Recommended breaker for input protection | 6 A … 16 A (Characteristic B, C or comparable) | 
| Type of protection | Transient surge protection | 
| Protective circuit/component | Varistor | 
| Nominal output voltage | 12 V DC | 
|---|---|
| Setting range of the output voltage (USet) | 12 V DC … 15 V DC (constant capacity) | 
| Nominal output current (IN) | 7.5 A | 
| Dynamic Boost (IDyn.Boost) | 12.75 A (≤ 60 °C (5 s)) | 
| Connection in parallel | yes, for redundancy and increased capacity | 
| Connection in series | yes | 
| Feedback voltage resistance | ≤ 25 V DC | 
| Protection against overvoltage at the output (OVP) | ≤ 18 V DC | 
| Control deviation | < 0.3 % (Static load change 10 % … 90 %) | 
| < 3 % (Dynamic load change 10 % … 90 %, (10 Hz)) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | < 35 mVPP (with nominal values) | 
| Output power | 90 W | 
| Typical response time | 300 ms | 
| Maximum power dissipation in no-load condition | < 0.6 W (230 V AC) | 
| < 0.6 W (120 V AC) | |
| Power loss nominal load max. | < 8.1 W (120 V AC) | 
| < 7.1 W (230 V AC) | 
| Net weight | 0.3 kg | 
|---|---|
| Efficiency | typ. 91.5 % (120 V AC) | 
| typ. 92.5 % (230 V AC) | |
| MTBF (IEC 61709, SN 29500) | > 1221000 h (25 °C) | 
| > 671000 h (40 °C) | |
| > 248000 h (60 °C) | |
| Insulation voltage input/output | 4 kV AC (type test) | 
| 3 kV AC (routine test) | |
| Degree of protection | IP20 | 
| Protection class | II | 
| Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 | 
| Connection method | Push-in connection | 
|---|---|
| Conductor cross section solid min. | 0.2 mm² | 
| Conductor cross section solid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 24 | 
| Conductor cross section AWG max. | 14 | 
| Stripping length | 10 mm | 
| Connection method | Push-in connection | 
|---|---|
| Conductor cross section solid min. | 0.2 mm² | 
| Conductor cross section solid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 24 | 
| Conductor cross section AWG max. | 14 | 
| Stripping length | 10 mm | 
| Connection method | Push-in connection | 
|---|---|
| Conductor cross section solid min. | 0.2 mm² | 
| Conductor cross section solid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 24 | 
| Conductor cross section AWG max. | 14 | 
| Stripping length | 10 mm | 
| EMC requirements, power plant | IEC 61850-3 | 
|---|---|
| EN 61000-6-5 | |
| Standard – Safety of transformers | EN 61558-2-16 | 
| Standard – safety for equipment for measurement, control, and laboratory use | IEC 61010-1 | 
| Standard – Safety extra-low voltage | IEC 61010-1 (SELV) | 
| IEC 61010-2-201 (PELV) | |
| Standard – Safe isolation | IEC 61558-2-16 | 
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 | 
| Overvoltage category EN 61010-1 | II (≤ 5000 m) | 
| Overvoltage category EN 62477-1 | III (≤ 2000 m) | 
| UL approvals | UL Listed UL 61010-1 | 
|---|---|
| UL Listed UL 61010-2-201 | |
| ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
| SIQ | CB-Scheme (IEC 61010-1, IEC 61010-2-201) | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
|---|---|
| Conducted noise emission | EN 55016 | 
| EN 61000-6-3 (Class B) | |
| Noise emission | EN 55016 | 
| EN 61000-6-3 (Class B) | |
| Harmonic currents | EN 61000-3-2 | 
| EN 61000-3-2 (Class A) | |
| Flicker | EN 61000-3-3 | 
| Electrostatic discharge | EN 61000-4-2 | 
| Contact discharge | 8 kV (Test Level 4) | 
| Discharge in air | 15 kV (Test Level 4) | 
| Electromagnetic HF field | EN 61000-4-3 | 
| Frequency range | 80 MHz … 1 GHz | 
| Test field strength | 20 V/m (Test Level 3) | 
| Frequency range | 1 GHz … 6 GHz | 
| Test field strength | 10 V/m (Test Level 3) | 
| Comments | Criterion A | 
| Fast transients (burst) | EN 61000-4-4 | 
| Input | 4 kV (Test Level 4 – asymmetrical) | 
| Output | 4 kV (Test Level 4 – asymmetrical) | 
| Signal | 4 kV (Test Level 4 – asymmetrical) | 
| Comments | Criterion A | 
| Surge voltage load (surge) | EN 61000-4-5 | 
| Input | 2 kV (Test Level 4 – symmetrical) | 
| 4 kV (Test Level 4 – asymmetrical) | |
| Output | 1 kV (Test Level 3 – symmetrical) | 
| 2 kV (Test Level 3 – asymmetrical) | |
| Signal | 0.5 kV (Test Level 2 – symmetrical) | 
| Comments | Criterion A | 
| Conducted interference | EN 61000-4-6 | 
| I/O/S | asymmetrical | 
| Frequency range | 0.15 MHz … 80 MHz | 
| Voltage | 10 V (Test Level 3) | 
| Comments | Criterion A | 
| Power frequency magnetic field | EN 61000-4-8 | 
| Frequency | 16.67 Hz | 
| 50 Hz | |
| 60 Hz | |
| Test field strength | 100 A/m | 
| Additional text | 60 s | 
| Comments | Criterion A | 
| Frequency | 50 Hz | 
| 60 Hz | |
| Frequency range | 50 Hz … 60 Hz | 
| Test field strength | 1 kA/m | 
| Additional text | 3 s | 
| Frequency | 0 Hz | 
| Test field strength | 300 A/m | 
| Additional text | DC, 60 s | 
| Voltage dips | EN 61000-4-11 | 
| Voltage | 100 V AC | 
| Frequency | 60 Hz | 
| Voltage dip | 70 % | 
| Number of periods | 0.5 / 1 / 30 periods | 
| Additional text | Test Level 2 | 
| Comments | Criterion A | 
| Voltage dip | 40 % | 
| Number of periods | 5 / 10 / 50 periods | 
| Additional text | Test Level 2 | 
| Comments | Criterion B | 
| Voltage dip | 0 % | 
| Number of periods | 0.5 / 1 / 5 / 50 periods | 
| Additional text | Test Level 2 | 
| Comments | Criterion B | 
| Pulse-shape magnetic field | EN 61000-4-9 | 
| Test field strength | 1000 A/m | 
| Comments | Criterion A | 
| Attenuated sinusoidal oscillations (ring wave) | EN 61000-4-12 | 
| Input | 2 kV (symmetrical) | 
| 4 kV (asymmetrical) | |
| Comments | Criterion A | 
| Asymmetrical conducted disturbance variables | EN 61000-4-16 | 
| Test level 1 | 16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) | 
| Voltage | 30 V (10 s) | 
| Test level 2 | 16.67 Hz 50 Hz 60 Hz (Test Level 2) | 
| Voltage | 300 V (1 s) | 
| Comments | Criterion A | 
| Attenuated oscillating wave | EN 61000-4-18 | 
| Voltage | 1 kV (symmetrical) | 
| 2.5 kV (asymmetrical) | |
| 1 kV (symmetrical) | |
| Comments | Criterion A | 
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
| Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. | 
| REACh SVHC | Lead 7439-92-1 | 
|---|