In the power range of up to 100Â W, QUINT POWER provides superior system availability in the smallest size. Preventative function monitoring and exceptional power reserves are available for applications in the low-power range.
Article Number | 2909575 |
---|---|
Width | 22.5 mm |
Height | 106 mm |
Depth | 90 mm |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 30 mm / 30 mm |
Degree of protection | IP20 |
---|---|
Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 |
Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | ≤ 5000 m (> 2000 m, observe derating) |
Input voltage range | 100 VÂ AC … 240 VÂ AC -15Â %Â …Â +10Â % |
---|---|
110 VÂ DC … 250 VÂ DC -20Â %Â …Â +40Â % | |
Dielectric strength maximum | 300 VÂ AC 30 s |
Frequency range (fN) | 50 Hz … 60 Hz -10Â % … +10Â % |
Discharge current to PE | < 0.25 mA (264Â VÂ AC, 60Â Hz) |
Current consumption | 0.46 A (100Â VÂ AC) |
0.37 A (120Â VÂ AC) | |
0.2 A (230 V AC) | |
0.2 A (240Â VÂ AC) | |
Nominal power consumption | 37 VA |
Inrush current | typ. 5.9 A (at 25 °C) |
Mains buffering time | typ. 43 ms (120Â VÂ AC) |
typ. 43 ms (230 VÂ AC) | |
Input fuse | 3.15 A (slow-blow, internal) |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Nominal output voltage | 24 VÂ DC |
---|---|
Setting range of the output voltage (USet) | 24 VÂ DC … 28 VÂ DC (constant capacity) |
Nominal output current (IN) | 1.3 A |
Static Boost (IStat.Boost) | 1.625 A (≤ 40 °C) |
Dynamic Boost (IDyn.Boost) | 2.6 A (≤ 60 °C (5 s)) |
Derating | > 60 °C (2.5%/K) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | ≤ 32 V DC |
Control deviation | < 0.5 % (Static load change 10Â % … 90Â %) |
< 2 % (Dynamic load change 10Â % … 90Â %, (10 Hz)) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 40 mVPPÂ (with nominal values) |
Output power | 30 W |
Typical response time | 500 ms |
Maximum power dissipation in no-load condition | < 0.4 W (230 V AC) |
< 0.4 W (120Â VÂ AC) | |
Power loss nominal load max. | < 3.7 W (120Â VÂ AC) |
< 3.1 W (230 V AC) |
Net weight | 0.188 kg |
---|---|
Environmental protection directive | RoHS Directive 2011/65/EU |
WEEE | |
Reach | |
Efficiency | typ. 89.2 % (120Â VÂ AC) |
typ. 90.7 % (230 V AC) | |
MTBF (IEC 61709, SN 29500) | > 1904000 h (25 °C) |
> 1107000 h (40 °C) | |
> 486000 h (60 °C) | |
Insulation voltage input/output | 4 kV AC (type test) |
3 kV AC (routine test) | |
Degree of protection | IP20V0 |
Protection class | II |
Inflammability class in acc. with UL 94 (housing / terminal blocks) | |
Assembly instructions | DIN rail mounting |
Connection method | Push-in connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 10 mm |
Connection method | Push-in connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 10 mm |
Connection method | Push-in connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 10 mm |
EMC requirements for noise immunity | ENÂ 61000-6-1 |
---|---|
ENÂ 61000-6-2 | |
EMC requirements for noise emission | ENÂ 61000-6-3 |
ENÂ 61000-6-4 | |
EMC requirements, power plant | IECÂ 61850-3 |
ENÂ 61000-6-5 | |
Standard – Safety of transformers | ENÂ 61558-2-16 |
Standard – Electrical safety | IECÂ 61010-2-201Â (SELV) |
Standard – safety for equipment for measurement, control, and laboratory use | IECÂ 61010-1 |
Standard – Safety extra-low voltage | IEC 61010-1 (SELV) |
IECÂ 61010-2-201 (PELV) | |
Standard – Safe isolation | IECÂ 61558-2-16 |
Standard – power supply devices for low voltage with DC output | ENÂ 61204-3 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Overvoltage category EN 61010-1 | II |
Overvoltage category EN 62477-1 | III (≤ 2000 m) |
UL approvals | UL Listed ULÂ 61010-1 |
---|---|
UL Listed ULÂ 61010-2-201 | |
UL 1310 Class 2 Power Units | |
ANSI/ULÂ 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
SIQ | CB-Scheme (IECÂ 61010-1, IECÂ 61010-2-201) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Conducted noise emission | ENÂ 55016 |
ENÂ 61000-6-3 (Class B) | |
Noise emission | ENÂ 55016 |
ENÂ 61000-6-3 (Class B) | |
Harmonic currents | ENÂ 61000-3-2 |
ENÂ 61000-3-2 (Class A) | |
Flicker | ENÂ 61000-3-3 |
Electrostatic discharge | EN 61000-4-2 |
Contact discharge | 8 kV (Test Level 4) |
Discharge in air | 8 kV (Test Level 3) |
Electromagnetic HF field | ENÂ 61000-4-3 |
Frequency range | 80 MHz … 1 GHz |
Test field strength | 20 V/m (Test Level 3) |
Frequency range | 1 GHz … 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | ENÂ 61000-4-4 |
Input | 4 kV (Test Level 4 – asymmetrical) |
Output | 4 kV (Test Level X – asymmetrical) |
Signal | 4 kV (Test Level X – asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge) | ENÂ 61000-4-5 |
Input | 2 kV (Test Level 4 – symmetrical) |
4 kV (Test Level 4 – asymmetrical) | |
Output | 1 kV (Test Level 3 – symmetrical) |
2 kV (Test Level 3 – asymmetrical) | |
Signal | 0.5 kV (Test Level 2 – symmetrical) |
Comments | Criterion A |
Conducted interference | ENÂ 61000-4-6 |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz … 80 MHz |
Voltage | 10 V (Test Level 3) |
Comments | Criterion A |
Power frequency magnetic field | ENÂ 61000-4-8 |
Frequency | 16.67 Hz |
50 Hz | |
60 Hz | |
Test field strength | 100 A/m |
Additional text | 60 s |
Comments | Criterion A |
Frequency | 50 Hz |
60 Hz | |
Frequency range | 50 Hz … 60 Hz |
Test field strength | 1 kA/m |
Additional text | 3 s |
Frequency | 0 Hz |
Test field strength | 300 A/m |
Additional text | DC, 60Â s |
Voltage dips | ENÂ 61000-4-11 |
Voltage | 100 VÂ AC |
Frequency | 60 Hz |
Voltage dip | 70 % |
Number of periods | 0.5 / 1 / 30 periods |
Additional text | Test Level 2 |
Comments | Criterion A |
Voltage dip | 40 % |
Number of periods | 5 / 10 / 50 periods |
Additional text | Test Level 2 |
Comments | Criterion B |
Voltage dip | 0 % |
Number of periods | 0.5 / 1 / 5 / 50 periods |
Additional text | Test Level 2 |
Comments | Criterion B |
Pulse-shape magnetic field | ENÂ 61000-4-9 |
Test field strength | 1000 A/m |
Comments | Criterion A |
Attenuated sinusoidal oscillations (ring wave) | ENÂ 61000-4-12 |
Input | 2 kV (symmetrical) |
4 kV (asymmetrical) | |
Comments | Criterion A |
Asymmetrical conducted disturbance variables | ENÂ 61000-4-16 |
Test level 1 | 16.67 Hz 50 Hz 60 Hz (Test Level 2) |
Voltage | 30 V (10 s) |
Test level 2 | 16.67 Hz 50 Hz 60 Hz (Test Level 4) |
Voltage | 300 V (1 s) |
Comments | Criterion A |
Criterion A | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 25; |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
Axmatic Sdn Bhd
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang