Axmatic – Your Trusted Phoenix Contact Distributor
Axmatic proudly stands as one of the largest distributors of Phoenix Contact products, offering a comprehensive range of terminal blocks, interface modules, power supplies, and relays.
Series Models: PT Series, ST Series, TB Series, UT Series, and UK Series, PTV Series, UKH Series, Micro Series.
Discover industry-leading Phoenix Contact power supplies, such as:
Get Your Phoenix Contact Catalog Today
Need detailed product information? Contact us at sales@axmatic.com to request your Phoenix Contact catalog.
TRIO POWER power supplies with standard functionality
TRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.
The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
| Width | 40 mm | 
| Height | 130 mm | 
| Depth | 115 mm | 
| Installation dimensions | |
| Installation distance right/left | 0 mm / 0 mm | 
| Installation distance top/bottom | 50 mm / 50 mm | 
| Degree of protection | IP20 | 
| Ambient temperature (operation) | -25 °C … 70 °C (> 55° C derating : 2.5%/K) | 
| Ambient temperature (storage/transport) | -40 °C … 85 °C | 
| Climatic class | 3K3 (in acc. with EN 60721) | 
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) | 
| Shock | 15g in all directions in acc. with IEC 60068-2-27 | 
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) | 
| 15 Hz … 150 Hz, 2.3g, 90 min. | 
| Nominal input voltage range | 2x / 3x 400 V AC … 500 V AC | 
| Input voltage range | 3x 320 V AC … 575 V AC (for 3-phase operation) | 
| 2x 360 V AC … 575 V AC (for 2-phase operation) | |
| Input voltage range AC | 3x 320 V AC … 575 V AC (for 3-phase operation) | 
| 2x 360 V AC … 575 V AC (for 2-phase operation) | |
| Voltage type of supply voltage | AC | 
| Inrush current | < 15 A | 
| Inrush current integral (I2t) | 0.2 A2s | 
| AC frequency range | 45 Hz … 65 Hz | 
| Mains buffering time | > 20 ms (3x 400 V AC) | 
| > 30 ms (3x 480 V AC) | |
| Current consumption | 3x 0.3 A (400 V AC) | 
| 3x 0.25 A (500 V AC) | |
| 2x 0.65 A (400 V AC) | |
| 2x 0.5 A (500 V AC) | |
| Nominal power consumption | 211 VA | 
| Protective circuit | Transient surge protection; Varistor | 
| Power factor (cos phi) | 0.64 | 
| Typical response time | < 1 s | 
| Permissible backup fuse | B6 B10 B16 | 
| Recommended breaker for input protection | 6 A … 16 A (Characteristics B, C, D, K) | 
| Discharge current to PE | < 3.5 mA | 
| Efficiency | 89 % (at 400 V AC and nominal values) | 
| Output characteristic | U/I | 
| Nominal output voltage | 24 V DC ±1 % | 
| Setting range of the output voltage (USet) | 22.5 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) | 
| Nominal output current (IN) | 5 A (UOUT = 24 V DC) | 
| Derating | 55 °C … 70 °C (2.5%/K) | 
| Feedback voltage resistance | 35 V DC | 
| Protection against overvoltage at the output (OVP) | < 35 V DC | 
| Max. capacitive load | unlimited | 
| Active current limitation | Approx 6 A (in the event of a short-circuit) | 
| Control deviation | < 1 % (change in load, static 10 % … 90 %) | 
| < 2 % (change in load, dynamic 10 % … 90 %) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | < 30 mVPP | 
| Output power | 120 W | 
| Peak switching voltages nominal load | < 30 mVPP | 
| Maximum no-load power dissipation | 4 W | 
| Power loss nominal load max. | 15 W | 
| Rise time | < 2 ms (UOUT (10 % … 90 %)) | 
| Connection in parallel | yes, for redundancy and increased capacity | 
| Connection in series | yes | 
| Item number | 2866462 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Sales Key | CM11 | 
| Product Key | CMPT33 | 
| Catalog Page | Page 176 (C-6-2013) | 
| GTIN | 4046356128544 | 
| Weight per Piece (including packing) | 743.7 g | 
| Weight per Piece (excluding packing) | 600 g | 
| Customs tariff number | 85044083 | 
| Country of origin | CN | 
| Connection method | Screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 24 | 
| Conductor cross section AWG max. | 14 | 
| Stripping length | 9 mm | 
| Screw thread | M2,5 | 
| Tightening torque, min | 0.4 Nm | 
| Tightening torque max | 0.5 Nm | 
| Connection method | Screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 16 | 
| Conductor cross section AWG max. | 12 | 
| Stripping length | 9 mm | 
| Screw thread | M2,5 | 
| Tightening torque, min | 0.4 Nm | 
| Tightening torque max | 0.5 Nm | 
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) | 
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 | 
| Standard – Electrical safety | EN 60950-1/VDE 0805 (SELV) | 
| Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 | 
| Standard – Safety extra-low voltage | EN 60950-1 (SELV) | 
| EN 60204 (PELV) | |
| Standard – Safe isolation | DIN VDE 0100-410 | 
| UL approvals | UL/C-UL listed UL 508 | 
| UL/C-UL Recognized UL 60950-1 | |
| Conformity/Approvals | |
| SIL in accordance with IEC 61508 | 0 | 
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | 
| EMC requirements for noise emission | EN 61000-6-3 | 
| EN 61000-6-4 | |
| EMC requirements for noise immunity | EN 61000-6-1 | 
| EN 61000-6-2 | |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 | 
| Electrostatic discharge | |
| Contact discharge | 8 kV (Test Level 4) | 
| Discharge in air | 8 kV (Test Level 3) | 
| Comments | Criterion A | 
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 | 
| Electromagnetic HF field | |
| Frequency range | 80 MHz … 1 GHz | 
| Test field strength | 10 V/m | 
| Frequency range | 1 GHz … 2 GHz | 
| Test field strength | 10 V/m | 
| Frequency range | 2 GHz … 3 GHz | 
| Test field strength | 10 V/m | 
| Comments | Criterion A | 
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 | 
| Fast transients (burst) | |
| Input | 4 kV (Test Level 4 – asymmetrical) | 
| Output | 4 kV (Test Level 4 – asymmetrical) | 
| Signal | 2 kV (Test Level 3 – asymmetrical) | 
| Comments | Criterion A | 
| Surge voltage load (surge) | |
| Standards/regulations | EN 61000-4-5 | 
| Input | 2 kV (Test Level 3 – symmetrical) | 
| 4 kV (Test Level 4 – asymmetrical) | |
| Output | 1 kV (Test Level 2 – symmetrical) | 
| 2 kV (Test Level 3 – asymmetrical) | |
| Comments | Criterion A | 
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 | 
| Conducted interference | |
| Frequency range | 0.15 MHz … 80 MHz | 
| Comments | Criterion A | 
| Voltage | 10 V (Test Level 3) | 
| Conducted interference | |
| Frequency range | 0.15 MHz … 80 MHz | 
| Comments | Criterion A | 
| Voltage | 10 V (Test Level 3) | 
| Voltage dips | |
| Standards/regulations | EN 61000-4-11 | 
| Emitted interference | |
| Standards/regulations | EN 61000-6-3 | 
| Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential | 
| Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential | 
| Weight | 0.7437 kg | 
|---|---|
| Dimensions | 11.5 × 4 × 13 cm |