Feed-through terminal block, nom. voltage: 630 V, nominal current: 32 A, connection method: Screw connection, number of connections: 4, number of positions: 1, cross section: 0.2 mm² – 6 mm², AWG: 24 – 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS 32
General
Article Number |
2775016 |
Number of positions |
1 |
Number of levels |
1 |
Number of connections |
4 |
Potentials |
1 |
Nominal cross section |
4 mm² |
Color |
gray |
Insulating material |
PA |
Flammability rating according to UL 94 |
V2 |
Mounting type |
NS 35/7,5 |
Rated surge voltage |
8 kV |
Degree of pollution |
3 |
Overvoltage category |
III |
Insulating material group |
I |
Maximum load current |
32 A (In the case of a 6 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors) |
Nominal current IN |
32 A (with 6 mm² conductor cross section) |
Nominal voltage UN |
630 V |
Open side panel |
Yes |
Shock protection test specification |
IEC 60529:1989-11 + AMD 1:1999-11 + AMD 2:2013-08 |
Back of the hand protection |
guaranteed |
Finger protection |
guaranteed |
Result of surge voltage test |
Test passed |
Result of power-frequency withstand voltage test |
Test passed |
Power frequency withstand voltage setpoint |
1.89 kV |
Result of the test for mechanical stability of terminal points (5 x conductor connection) |
Test passed |
Result of flexion and pull-out test |
Test passed |
Bending test rotation speed |
10 rpm |
Bending test turns |
135 |
Bending test conductor cross section/weight |
0.2 mm² / 0.2 kg |
|
4 mm² / 0.9 kg |
Tensile test result |
Test passed |
Result of tight fit on support |
Test passed |
Tight fit on carrier |
NS 32/NS 35 |
Setpoint |
1 N |
Result of voltage-drop test |
Test passed |
Result of temperature-rise test |
Test passed |
Requirement temperature-rise test |
Increase in temperature ≤ 45 K |
Short circuit stability result |
Test passed |
Conductor cross section short circuit testing |
4 mm² |
Short-time current |
0.48 kA |
Conductor cross section short circuit testing |
6 mm² |
Short-time current |
0.72 kA |
Result of thermal test |
Test passed |
Proof of thermal characteristics (needle flame) effective duration |
30 s |
Relative insulation material temperature index (Elec., UL 746 B) |
125 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) |
125 °C |
Dimensions
Width |
6.2 mm |
End cover width |
1.5 mm |
Length |
63.5 mm |
Height NS 35/7,5 |
47 mm |
Height NS 35/15 |
54.5 mm |
Height NS 32 |
52 mm |
Connection data
Connection |
1 level |
Connection method |
Screw connection |
Screw thread |
M3 |
Stripping length |
8 mm |
Tightening torque, min |
0.5 Nm |
Tightening torque max |
0.6 Nm |
Connection in acc. with standard |
IEC 60947-7-1 |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
10 |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
Min. AWG conductor cross section, flexible |
24 |
Max. AWG conductor cross section, flexible |
12 |
Conductor cross section flexible, with ferrule without plastic sleeve min. |
0.25 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. |
4 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. |
0.25 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. |
1.5 mm² |
Cross section with insertion bridge, solid max. |
2.5 mm² |
Cross section with insertion bridge, stranded max. |
2.5 mm² |
2 conductors with same cross section, solid min. |
0.2 mm² |
2 conductors with same cross section, solid max. |
1 mm² |
2 conductors with same cross section, stranded min. |
0.2 mm² |
2 conductors with same cross section, stranded max. |
1.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum |
0.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum |
1 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum |
0.25 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum |
1.5 mm² |
Internal cylindrical gage |
A3 |
Ambient conditions
Operating temperature |
-60 °C … 105 °C (max. short-term operating temperature 125°C) |
Ambient temperature (storage/transport) |
-25 °C … 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Permissible humidity (storage/transport) |
30 % … 70 % |
Ambient temperature (assembly) |
-5 °C … 70 °C |
Ambient temperature (actuation) |
-5 °C … 70 °C |
Standards and Regulations
Connection in acc. with standard |
CSA |
|
IEC 60947-7-1 |
Flammability rating according to UL 94 |
V2 |
Environmental Product Compliance
China RoHS |
Environmentally Friendly Use Period = 50 years |
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |