| Width | 59 mm | 
|---|---|
| Height | 130 mm | 
| Depth | 129 mm | 
| 125 mm (Device depth (DIN rail mounting)) | |
| Installation distance right/left (active, passive) | 0 mm / 0 mm (POut ≥50% ) | 
| Installation distance top/bottom (active, passive) | 30 mm / 30 mm (POut ≥50% ) | 
| Ambient temperature (operation) | -25 °C … 70 °C (> 55 °C Derating: 2.5 %/K) | 
|---|---|
| Ambient temperature (start-up type tested) | -40 °C | 
| Ambient temperature (storage/transport) | -40 °C … 85 °C | 
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) | 
| Maximum altitude | ≤ 3000 m (> 2000 m, Derating: 10 %/1000 m) | 
| Degree of pollution | 2 | 
| Climatic class | 3K3 (in acc. with EN 60721) | 
| Nominal input voltage range | 100 V AC … 240 V AC | 
|---|---|
| Input voltage range | 100 V AC … 240 V AC -15 % … +10 % | 
| Derating | < 90 V AC (1 %/V) | 
| Frequency range (fN) | 50 Hz … 60 Hz 10 % | 
| Typical national grid voltage | 120 V AC | 
| 230 V AC | |
| Voltage type of supply voltage | AC | 
| Current consumption | 5.4 A (100 V AC) | 
| 4.4 A (120 V AC) | |
| 2.3 A (230 V AC) | |
| 2.2 A (240 V AC) | |
| Discharge current to PE | < 3.5 mA | 
| Mains buffering time | typ. 17 ms (120 V AC) | 
| typ. 18 ms (230 V AC) | |
| Switch-on time | typ. 1 s | 
| Inrush current | typ. 15 A (at 25 °C) | 
| Inrush current integral (I2t) | < 1 A2s | 
| Type of protection | Transient protection | 
| Protective circuit/component | Varistor, gas-filled surge arrester | 
| Device mains fuse | 8 A internal (device protection), fast-blow | 
| Recommended breaker for input protection | 10 A … 16 A (Characteristic B, C, D, K or comparable) | 
| Nominal output voltage | 24 V DC | 
|---|---|
| Setting range of the output voltage (USet) | 24 V DC … 28 V DC (> 24 V DC, constant capacity restricted) | 
| Nominal output current (IN) | 20 A | 
| Control deviation | < 1 % (change in load, static 10 % … 90 %) | 
| < 3 % (change in load, dynamic 10 % … 90 %) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Short-circuit-proof | yes | 
| No-load proof | yes | 
| Residual ripple | typ. 70 mVPP (with nominal values) | 
| Connection in parallel | yes, for redundancy | 
| Connection in series | yes, for increased output voltage | 
| Feedback voltage resistance | ≤ 35 V DC | 
| Protection against overvoltage at the output (OVP) | ≤ 35 V DC | 
| Rise time | < 1 s (UOut = 10 % … 90 %) | 
| Derating | 55 °C … 70 °C | 
| Crest factor | typ. 1,667 (120 V AC) | 
| typ. 1,75 (230 V AC) | |
| Minimum no-load power dissipation | < 2.9 W (120 V AC) | 
| Maximum power dissipation in no-load condition | < 3 W (230 V AC) | 
| Minimum nominal load power dissipation | < 37 W (120 V AC) | 
| Power loss nominal load max. | < 28 W (230 V AC) | 
| Article Number | 2910105 | 
|---|---|
| Net weight | 1 kg | 
| Environmental protection directive | RoHS Directive 2011/65/EU | 
| WEEE | |
| Reach | |
| Efficiency | typ. 93 % (120 V AC) | 
| typ. 94.6 % (230 V AC) | |
| MTBF (IEC 61709, SN 29500) | > 900000 h (25 °C) | 
| > 530000 h (40 °C) | |
| > 280000 h (55 °C) | |
| Insulation voltage input/output | 4 kV AC (type test) | 
| 3 kV AC (routine test) | |
| Insulation voltage input / PE | 3.5 kV AC (type test) | 
| 2.4 kV AC (routine test) | |
| Degree of protection | IP20 | 
| Protection class | I | 
| Housing material | Aluminum (AlMg3) / sheet steel, zinc-plated | 
| Foot latch material | Sheet steel, zinc-plated | 
| Mounting position | horizontal DIN rail NS 35, EN 60715 | 
| Assembly instructions | alignable: 0 mm horizontally, 30 mm vertically | 
| Connection method | Screw connection | 
|---|---|
| Stripping length | 8 mm | 
| Conductor cross section solid | 0.2 mm² … 6 mm² | 
| Conductor cross section flexible | 0.2 mm² … 4 mm² | 
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² … 4 mm² | 
| Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) | 0.25 mm² … 4 mm² | 
| Conductor cross section AWG | 24 … 10 (Cu) | 
| Torque | 0.5 Nm … 0.6 Nm | 
| Connection method | Screw connection | 
|---|---|
| Stripping length | 8 mm | 
| Conductor cross section solid | 0.2 mm² … 6 mm² | 
| Conductor cross section flexible | 0.2 mm² … 4 mm² | 
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² … 4 mm² | 
| Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) | 0.25 mm² … 4 mm² | 
| Conductor cross section AWG | 24 … 10 (Cu) | 
| Torque | 0.5 Nm … 0.6 Nm | 
| Connection method | Screw connection | 
|---|---|
| Stripping length | 8 mm | 
| Conductor cross section solid | 0.2 mm² … 6 mm² | 
| Conductor cross section flexible | 0.2 mm² … 4 mm² | 
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² … 4 mm² | 
| Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) | 0.25 mm² … 4 mm² | 
| Conductor cross section AWG | 24 … 10 (Cu) | 
| Torque | 0.5 Nm … 0.6 Nm | 
| Types of signaling | LED DC OK – signal state operation (UN = 24 V DC, IOut = IN) | 
|---|
| Maximum contact load | 30 V AC/DC | 
|---|---|
| 100 mA | 
| Connection level | 3.x | 
|---|---|
| Connection labeling | 3.1 (13), 3.2 (14) | 
| Function | Operating state forwarding | 
| Switch contact | OptoMOS | 
| Switching voltage | max. 30 V AC | 
| max. 60 V DC | |
| Current carrying capacity | max. 50 mA | 
| State condition | UOUT > 0,9 x UN (Contact closed) | 
| UOUT < 0,9 x UN (Contact open) | 
| EMC requirements for noise immunity | EN 61000-6-2 | 
|---|---|
| Standard designation | Safety of power supply units up to 1100 V (insulation distances) | 
| Standards/regulations | DIN EN 61558-2-16 | 
| Standard designation | Electrical safety | 
| Standards/regulations | IEC 61010-2-201 (SELV) | 
| Standard designation | Equipping high voltage installations with electronic equipment | 
| Standards/regulations | EN 50178/VDE 0160 (PELV) | 
| Standard designation | Safety for equipment for measurement, control, and laboratory use | 
| Standards/regulations | IEC 61010-1 | 
| Standard designation | Protective extra-low voltage | 
| Standards/regulations | IEC 61010-1 (SELV) | 
| IEC 61010-2-201 (PELV) | |
| Standard designation | Safe isolation | 
| Standards/regulations | IEC 61558-2-16 | 
| IEC 61010-2-201 | |
| Standard designation | Limitation of harmonic line currents | 
| Standards/regulations | EN 61000-3-2 | 
| Standard designation | Requirement of the semiconductor industry with regard to mains voltage dips | 
| Standards/regulations | SEMI F47 – 0706 (185 V AC) | 
| Overvoltage category EN 61010-1 | II (≤ 3000 m) | 
| Overvoltage category EN 62477-1 | III (≤3000 m) | 
| Designation | UL | 
|---|---|
| Identification | UL/C-UL Listed UL 61010-1 | 
| Designation | UL | 
| Identification | UL/C-UL Listed UL 61010-2-201 | 
| Designation | UL | 
| Identification | UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | 
| Designation | SIQ | 
| Identification | CB scheme (IEC 61010-1, IEC 61010-2-201) | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
|---|---|
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | 
| Conducted noise emission | EN 55016 | 
| EN 61000-6-3 (Class B) | |
| Noise emission | EN 55016 | 
| EN 61000-6-3 (Class B) | |
| Harmonic currents | EN 61000-3-2 | 
| EN 61000-3-2 (Class A) | |
| Electrostatic discharge | EN 61000-4-2 | 
| Contact discharge | 6 kV (Test Level 3) | 
| Discharge in air | 8 kV (Test Level 3) | 
| Electromagnetic HF field | EN 61000-4-3 | 
| Frequency range | 80 MHz … 1 GHz | 
| Test field strength | 10 V/m (Test Level 3) | 
| Frequency range | 1 GHz … 6 GHz | 
| Test field strength | 10 V/m (Test Level 3) | 
| Comments | Criterion A | 
| Fast transients (burst) | EN 61000-4-4 | 
| Input | 4 kV (Test Level 4 – asymmetrical) | 
| Output | 2 kV (Test Level 3 – asymmetrical) | 
| Comments | Criterion A | 
| Surge voltage load (surge) | EN 61000-4-5 | 
| Input | 2 kV (Test Level 3 – symmetrical) | 
| 4 kV (Test Level 4 – asymmetrical) | |
| Output | 1 kV (Test Level 2 – symmetrical) | 
| 2 kV (Test Level 3 – asymmetrical) | |
| Comments | Criterion A | 
| Conducted interference | EN 61000-4-6 | 
| Frequency range | 0.15 MHz … 80 MHz | 
| Voltage | 10 V (Test Level 3) | 
| Comments | Criterion A | 
| Voltage dips | EN 61000-4-11 | 
| Voltage | 230 V AC | 
| Frequency | 50 Hz | 
| Voltage dip | 70 % | 
| Number of periods | 25 / 30 periods | 
| Comments | Criterion A | 
| Voltage dip | 40 % | 
| Number of periods | 12 periods | 
| Additional text | Test Level 2 | 
| Comments | Criterion A | 
| Voltage dip | 0 % | 
| Number of periods | 1 period | 
| Additional text | Test Level 2 | 
| Comments | Criterion B | 
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
| REACh SVHC | Lead 7439-92-1 | 
|---|---|
| China RoHS | Environmentally Friendly Use Period = 25; | 
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |