ATS22C41Q
| Main | ||||
| Part Number | ATS22D17Q | ATS22D32Q | ATS22D47Q | ATS22D62Q | 
| Range of product | Altistart 22 | Altistart 22 | Altistart 22 | Altistart 22 | 
| Product or component type | Soft starter | Soft starter | Soft starter | Soft starter | 
| Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors | 
| Product specific application | Pumps and fans | Pumps and fans | Pumps and fans | Pumps and fans | 
| Component name | ATS22 | ATS22 | ATS22 | ATS22 | 
| Network number of phases | 3 phases | 3 phases | 3 phases | 3 phases | 
| [Us] rated supply voltage | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 
| motor power kW | 4 kW 230 V 7.5 kW 400 V 7.5 kW 440 V | 15 kW 400 V 15 kW 440 V 7.5 kW 230 V | 11 kW 230 V 22 kW 400 V 22 kW 440 V | 15 kW 230 V 30 kW 400 V 30 kW 440 V | 
| Factory setting current | 14.8 A | 28.5 A | 42 A | 57 A | 
| power dissipation in W | 39 W for standard applications | 44 W for standard applications | 48 W for standard applications | 59 W for standard applications | 
| Utilisation category | AC-53A | AC-53A | AC-53A | AC-53A | 
| Type of start | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | 
| IcL starter rating | 17 A for connection in the motor supply line for standard applications | 32 A for connection in the motor supply line for standard applications | 47 A for connection in the motor supply line for standard applications | 62 A for connection in the motor supply line for standard applications | 
| IP degree of protection | IP20 | IP20 | IP20 | IP20 | 
| Complementary | ||||
| Assembly style | With heat sink | With heat sink | With heat sink | With heat sink | 
| Function available | Internal bypass | Internal bypass | Internal bypass | Internal bypass | 
| Supply voltage limits | 195…484 V | 195…484 V | 195…484 V | 195…484 V | 
| supply frequency | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 
| Network frequency | 45…66 Hz | 45…66 Hz | 45…66 Hz | 45…66 Hz | 
| Device connection | In the motor supply line To the motor delta terminals | In the motor supply line To the motor delta terminals | To the motor delta terminals In the motor supply line | To the motor delta terminals In the motor supply line | 
| [Uc] control circuit voltage | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 
| Control circuit consumption | 20 W | 20 W | 20 W | 20 W | 
| Discrete output number | 2 | 2 | 2 | 2 | 
| discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | 
| minimum switching current | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 
| maximum switching current | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 
| Discrete input number | 3 | 3 | 3 | 3 | 
| discrete input type | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | 
| discrete input voltage | 24 V <= 30 V | 24 V <= 30 V | 24 V <= 30 V | 24 V <= 30 V | 
| discrete input logic | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | 
| output current | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 
| PTC probe input | 750 Ohm | 750 Ohm | 750 Ohm | 750 Ohm | 
| Communication port protocol | Modbus | Modbus | Modbus | Modbus | 
| connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 1 RJ45 | 
| Communication data link | Serial | Serial | Serial | Serial | 
| Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop | RS485 multidrop | 
| Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 
| Installed device | 31 | 31 | 31 | 31 | 
| protection type | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | 
| Marking | CE | CE | CE | CE | 
| Type of cooling | Forced convection | Forced convection | Forced convection | Forced convection | 
| Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | 
| Height | 265 mm | 265 mm | 265 mm | 295 mm | 
| Width | 130 mm | 130 mm | 130 mm | 145 mm | 
| Depth | 169 mm | 169 mm | 169 mm | 207 mm | 
| Net weight | 7 kg | 7 kg | 7 kg | 12 kg | 
| Motor power range AC-3 | 4…6 kW at 200…240 V 3 phases 7…11 kW at 380…440 V 3 phases | 7…11 kW at 200…240 V 3 phases 15…25 kW at 380…440 V 3 phases | 7…11 kW at 200…240 V 3 phases 15…25 kW at 380…440 V 3 phases | 15…25 kW at 200…240 V 3 phases 30…50 kW at 380…440 V 3 phases | 
| Motor starter type | Soft starter | Soft starter | Soft starter | Soft starter | 
| Environment | ||||
| electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | 
| Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | 
| Product certifications | UL GOST CSA CCC C-Tick | GOST C-Tick UL CCC CSA | CCC C-Tick UL GOST CSA | C-Tick CCC UL CSA GOST | 
| vibration resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 
| shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 
| Noise level | 45 dB | 45 dB | 45 dB | 45 dB | 
| pollution degree | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | 
| relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 
| ambient air temperature for operation | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | 
| Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C | 
| operating altitude | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | 
| Packing Units | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 28.0 cm | 27 cm | 26.924 cm | 31.0 cm | 
| Package 1 Width | 22.0 cm | 22 cm | 22.098 cm | 23.5 cm | 
| Package 1 Length | 33.5 cm | 33.5 cm | 33.274 cm | 36.0 cm | 
| Package 1 Weight | 5.597 kg | 5.6 kg | 5.606 kg | 8.262 kg | 
| Unit Type of Package 2 | P06 | P06 | P06 | P06 | 
| Number of Units in Package 2 | 10 | 10 | 10 | 6 | 
| Package 2 Height | 73.5 cm | 73.5 cm | 73.5 cm | 73.5 cm | 
| Package 2 Width | 80.0 cm | 80 cm | 80 cm | 80.0 cm | 
| Package 2 Length | 60.0 cm | 60 cm | 60 cm | 60.0 cm | 
| Package 2 Weight | 69.7 kg | 69.52 kg | 69.76 kg | 64.0 kg | 
| Contractual warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | ||||
| Part Number | ATS22D75Q | ATS22D88Q | ATS22C11Q | ATS22C14Q | 
| Range of product | Altistart 22 | Altistart 22 | Altistart 22 | Altistart 22 | 
| Product or component type | Soft starter | Soft starter | Soft starter | Soft starter | 
| Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors | 
| Product specific application | Pumps and fans | Pumps and fans | Pumps and fans | Pumps and fans | 
| Component name | ATS22 | ATS22 | ATS22 | ATS22 | 
| Network number of phases | 3 phases | 3 phases | 3 phases | 3 phases | 
| [Us] rated supply voltage | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 
| motor power kW | 37 kW 400 V 37 kW 440 V 18.5 kW 230 V | 22 kW 230 V 45 kW 400 V 45 kW 440 V | 39 kW 230 V 55 kW 400 V 55 kW 440 V | 37 kW 230 V 75 kW 400 V 75 kW 440 V | 
| Factory setting current | 69 A | 81 A | 100 A | 131 A | 
| power dissipation in W | 63 W for standard applications | 66 W for standard applications | 73 W for standard applications | 82 W for standard applications | 
| Utilisation category | AC-53A | AC-53A | AC-53A | AC-53A | 
| Type of start | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | 
| IcL starter rating | 75 A for connection in the motor supply line for standard applications | 88 A for connection in the motor supply line for standard applications | 110 A for connection in the motor supply line for standard applications | 140 A for connection in the motor supply line for standard applications | 
| IP degree of protection | IP20 | IP20 | IP20 | IP00 | 
| Complementary | ||||
| Assembly style | With heat sink | With heat sink | With heat sink | With heat sink | 
| Function available | Internal bypass | Internal bypass | Internal bypass | Internal bypass | 
| Supply voltage limits | 195…484 V | 195…484 V | 195…484 V | 195…484 V | 
| supply frequency | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 
| Network frequency | 45…66 Hz | 45…66 Hz | 45…66 Hz | 45…66 Hz | 
| Device connection | In the motor supply line To the motor delta terminals | To the motor delta terminals In the motor supply line | In the motor supply line To the motor delta terminals | In the motor supply line To the motor delta terminals | 
| [Uc] control circuit voltage | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 
| Control circuit consumption | 20 W | 20 W | 20 W | 20 W | 
| Discrete output number | 2 | 2 | 2 | 2 | 
| discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | 
| minimum switching current | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 
| maximum switching current | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 
| Discrete input number | 3 | 3 | 3 | 3 | 
| discrete input type | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | 
| discrete input voltage | 24 V <= 30 V | 24 V <= 30 V | 24 V <= 30 V | 24 V <= 30 V | 
| discrete input logic | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | 
| output current | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 
| PTC probe input | 750 Ohm | 750 Ohm | 750 Ohm | 750 Ohm | 
| Communication port protocol | Modbus | Modbus | Modbus | Modbus | 
| connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 1 RJ45 | 
| Communication data link | Serial | Serial | Serial | Serial | 
| Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop | RS485 multidrop | 
| Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 
| Installed device | 31 | 31 | 31 | 31 | 
| protection type | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | 
| Marking | CE | CE | CE | CE | 
| Type of cooling | Forced convection | Forced convection | Forced convection | Forced convection | 
| Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | 
| Height | 295 mm | 295 mm | 356 mm | 356 mm | 
| Width | 145 mm | 145 mm | 150 mm | 150 mm | 
| Depth | 207 mm | 207 mm | 229.5 mm | 229.5 mm | 
| Net weight | 12 kg | 12 kg | 18 kg | 18 kg | 
| Motor power range AC-3 | 15…25 kW at 200…240 V 3 phases 30…50 kW at 380…440 V 3 phases | 15…25 kW at 200…240 V 3 phases 30…50 kW at 380…440 V 3 phases | 30…50 kW at 200…240 V 3 phases 55…100 kW at 380…440 V 3 phases | 30…50 kW at 200…240 V 3 phases 55…100 kW at 380…440 V 3 phases | 
| Motor starter type | Soft starter | Soft starter | Soft starter | Soft starter | 
| Environment | ||||
| electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | 
| Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | 
| Product certifications | CSA UL GOST CCC C-Tick | CCC CSA UL GOST C-Tick | UL CSA GOST C-Tick CCC | UL CSA C-Tick GOST CCC | 
| vibration resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 
| shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 
| Noise level | 45 dB | 45 dB | 56 dB | 56 dB | 
| pollution degree | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | 
| relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 
| ambient air temperature for operation | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | 
| Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C | 
| operating altitude | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | 
| Packing Units | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 31.0 cm | 23.0 cm | 25.0 cm | 25.5 cm | 
| Package 1 Width | 23.5 cm | 30.8 cm | 33.0 cm | 32.5 cm | 
| Package 1 Length | 36.0 cm | 35.8 cm | 41.0 cm | 41.5 cm | 
| Package 1 Weight | 8.221 kg | 8.277 kg | 12.868 kg | 13.207 kg | 
| Unit Type of Package 2 | P06 | P06 | P06 | P06 | 
| Number of Units in Package 2 | 6 | 6 | 4 | 4 | 
| Package 2 Height | 73.5 cm | 73.5 cm | 73.5 cm | 63.0 cm | 
| Package 2 Width | 80.0 cm | 80.0 cm | 80.0 cm | 80.0 cm | 
| Package 2 Length | 60.0 cm | 60.0 cm | 60.0 cm | 60.0 cm | 
| Package 2 Weight | 63.136 kg | 63.184 kg | 64.472 kg | 65.828 kg | 
| Contractual warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | ||||
| Part Number | ATS22C17Q | ATS22C21Q | ATS22C25Q | ATS22C32Q | 
| Range of product | Altistart 22 | Altistart 22 | Altistart 22 | Altistart 22 | 
| Product or component type | Soft starter | Soft starter | Soft starter | Soft starter | 
| Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors | 
| Product specific application | Pumps and fans | Pumps and fans | Pumps and fans | Pumps and fans | 
| Component name | ATS22 | ATS22 | ATS22 | ATS22 | 
| Network number of phases | 3 phases | 3 phases | 3 phases | 3 phases | 
| [Us] rated supply voltage | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 
| motor power kW | 45 kW 230 V 90 kW 400 V 90 kW 440 V | 110 kW 400 V 110 kW 440 V 55 kW 230 V | 132 kW 400 V 132 kW 440 V 75 kW 230 V | 160 kW 400 V 160 kW 440 V 90 kW 230 V | 
| Factory setting current | 162 A | 195 A | 233 A | 285 A | 
| power dissipation in W | 91 W for standard applications | 117 W for standard applications | 129 W for standard applications | 150 W for standard applications | 
| Utilisation category | AC-53A | AC-53A | AC-53A | AC-53A | 
| Type of start | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | 
| IcL starter rating | 170 A for connection in the motor supply line for standard applications | 210 A for connection in the motor supply line for standard applications | 250 A for connection in the motor supply line for standard applications | 320 A for connection in the motor supply line for standard applications | 
| IP degree of protection | IP00 | IP00 | IP00 | IP00 | 
| Complementary | ||||
| Assembly style | With heat sink | With heat sink | With heat sink | With heat sink | 
| Function available | Internal bypass | Internal bypass | Internal bypass | Internal bypass | 
| Supply voltage limits | 195…484 V | 195…484 V | 195…484 V | 195…484 V | 
| supply frequency | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 
| Network frequency | 45…66 Hz | 45…66 Hz | 45…66 Hz | 45…66 Hz | 
| Device connection | To the motor delta terminals In the motor supply line | To the motor delta terminals In the motor supply line | In the motor supply line To the motor delta terminals | To the motor delta terminals In the motor supply line | 
| [Uc] control circuit voltage | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 
| Control circuit consumption | 20 W | 20 W | 20 W | 20 W | 
| Discrete output number | 2 | 2 | 2 | 2 | 
| discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | 
| minimum switching current | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 
| maximum switching current | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 
| Discrete input number | 3 | 3 | 3 | 3 | 
| discrete input type | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | 
| discrete input voltage | 24 V <= 30 V | 24 V <= 30 V | 24 V <= 30 V | 24 V <= 30 V | 
| discrete input logic | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | 
| output current | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 
| PTC probe input | 750 Ohm | 750 Ohm | 750 Ohm | 750 Ohm | 
| Communication port protocol | Modbus | Modbus | Modbus | Modbus | 
| connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 1 RJ45 | 
| Communication data link | Serial | Serial | Serial | Serial | 
| Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop | RS485 multidrop | 
| Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 
| Installed device | 31 | 31 | 31 | 31 | 
| protection type | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | 
| Marking | CE | CE | CE | CE | 
| Type of cooling | Forced convection | Forced convection | Forced convection | Forced convection | 
| Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | 
| Height | 356 mm | 425 mm | 425 mm | 425 mm | 
| Width | 150 mm | 206 mm | 206 mm | 206 mm | 
| Depth | 229.5 mm | 299 mm | 299 mm | 299 mm | 
| Net weight | 18 kg | 33 kg | 33 kg | 33 kg | 
| Motor power range AC-3 | 30…50 kW at 200…240 V 3 phases 55…100 kW at 380…440 V 3 phases | 55…100 kW at 200…240 V 3 phases 110…220 kW at 380…440 V 3 phases | 55…100 kW at 200…240 V 3 phases 110…220 kW at 380…440 V 3 phases | 55…100 kW at 200…240 V 3 phases 110…220 kW at 380…440 V 3 phases | 
| Motor starter type | Soft starter | Soft starter | Soft starter | Soft starter | 
| Environment | ||||
| electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | 
| Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | 
| Product certifications | CSA C-Tick GOST UL CCC | CCC UL GOST CSA C-Tick | C-Tick GOST UL CCC CSA | UL CCC C-Tick CSA GOST | 
| vibration resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 
| shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 
| Noise level | 56 dB | 56 dB | 56 dB | 56 dB | 
| pollution degree | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | 
| relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 
| ambient air temperature for operation | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | 
| Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C | 
| operating altitude | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | 
| Packing Units | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 25.0 cm | 46.000 cm | 49.0 cm | 49.0 cm | 
| Package 1 Width | 33.0 cm | 40.000 cm | 36.7 cm | 36.5 cm | 
| Package 1 Length | 41.0 cm | 60.000 cm | 55.5 cm | 54.5 cm | 
| Package 1 Weight | 13.218 kg | 24.500 kg | 26.25 kg | 24.5 kg | 
| Unit Type of Package 2 | P06 | P06 | PAL | |
| Number of Units in Package 2 | 4 | 2 | 1 | |
| Package 2 Height | 73.5 cm | 77.0 cm | 49.0 cm | |
| Package 2 Width | 80.0 cm | 80.0 cm | 36.5 cm | |
| Package 2 Length | 60.0 cm | 60.0 cm | 54.5 cm | |
| Package 2 Weight | 64.064 kg | 61.0 kg | 24.5 kg | |
| Contractual warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | |||
| Part Number | ATS22C41Q | ATS22C48Q | ATS22C59Q | 
| Range of product | Altistart 22 | Altistart 22 | Altistart 22 | 
| Product or component type | Soft starter | Soft starter | Soft starter | 
| Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | 
| Product specific application | Pumps and fans | Pumps and fans | Pumps and fans | 
| Component name | ATS22 | ATS22 | ATS22 | 
| Network number of phases | 3 phases | 3 phases | 3 phases | 
| [Us] rated supply voltage | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 230…440 V – 15…10 % | 
| motor power kW | 110 kW 230 V 220 kW 400 V 220 kW 440 V | 132 kW 230 V 250 kW 400 V 250 kW 440 V | 160 kW 230 V 315 kW 400 V 355 kW 440 V | 
| Factory setting current | 388 A | 437 A | 560 A | 
| power dissipation in W | 177 W for standard applications | 218 W for standard applications | 251 W for standard applications | 
| Utilisation category | AC-53A | AC-53A | AC-53A | 
| Type of start | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | Start with torque control (current limited to 3.5 In) | 
| IcL starter rating | 410 A for connection in the motor supply line for standard applications | 480 A for connection in the motor supply line for standard applications | 590 A for connection in the motor supply line for standard applications | 
| IP degree of protection | IP00 | IP00 | IP00 | 
| Complementary | |||
| Assembly style | With heat sink | With heat sink | With heat sink | 
| Function available | Internal bypass | Internal bypass | Internal bypass | 
| Supply voltage limits | 195…484 V | 195…484 V | 195…484 V | 
| supply frequency | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 50…60 Hz – 10…10 % | 
| Network frequency | 45…66 Hz | 45…66 Hz | 45…66 Hz | 
| Device connection | To the motor delta terminals In the motor supply line | In the motor supply line To the motor delta terminals | To the motor delta terminals In the motor supply line | 
| [Uc] control circuit voltage | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 230 V – 15…10 % 50/60 Hz | 
| Control circuit consumption | 20 W | 20 W | 20 W | 
| Discrete output number | 2 | 2 | 2 | 
| discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O | 
| minimum switching current | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 100 mA at 12 V DC (relay outputs) | 
| maximum switching current | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs | 
| Discrete input number | 3 | 3 | 3 | 
| discrete input type | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm | 
| discrete input voltage | 24 V <= 30 V | 24 V <= 30 V | 24 V <= 30 V | 
| discrete input logic | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | 
| output current | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 0.4…1 Icl adjustable | 
| PTC probe input | 750 Ohm | 750 Ohm | 750 Ohm | 
| Communication port protocol | Modbus | Modbus | Modbus | 
| connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 
| Communication data link | Serial | Serial | Serial | 
| Physical interface | RS485 multidrop | RS485 multidrop | RS485 multidrop | 
| Transmission rate | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 4800, 9600 or 19200 bps | 
| Installed device | 31 | 31 | 31 | 
| protection type | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | Phase failure: line Thermal protection: motor Thermal protection: starter | 
| Marking | CE | CE | CE | 
| Type of cooling | Forced convection | Forced convection | Forced convection | 
| Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | 
| Height | 425 mm | 455 mm | 455 mm | 
| Width | 206 mm | 304 mm | 304 mm | 
| Depth | 299 mm | 339.7 mm | 339.7 mm | 
| Net weight | 33 kg | 50 kg | 50 kg | 
| Motor power range AC-3 | 110…220 kW at 380…440 V 3 phases 110…220 kW at 200…240 V 3 phases | 110…220 kW at 200…240 V 3 phases 250…500 kW at 380…440 V 3 phases | 110…220 kW at 200…240 V 3 phases 250…500 kW at 380…440 V 3 phases | 
| Motor starter type | Soft starter | Soft starter | Soft starter | 
| Environment | |||
| electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 | 
| Standards | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | EN/IEC 60947-4-2 | 
| Product certifications | GOST CCC CSA UL C-Tick | GOST CSA UL C-Tick CCC | UL CCC C-Tick CSA GOST | 
| vibration resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 | 
| shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | 
| Noise level | 56 dB | 56 dB | 56 dB | 
| pollution degree | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | Level 2 conforming to IEC 60664-1 | 
| relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | 
| ambient air temperature for operation | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | -10…40 °C (without derating) 40…60 °C (with current derating 2.2 % per °C) | 
| Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | 
| operating altitude | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | <= 1000 m without derating > 1000…< 2000 m with current derating of 2.2 % per additional 100 m | 
| Packing Units | |||
| Unit Type of Package 1 | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 
| Package 1 Height | 49.0 cm | 54.5 cm | 54.864 cm | 
| Package 1 Width | 37.0 cm | 40.0 cm | 57.15 cm | 
| Package 1 Length | 54.5 cm | 57.5 cm | 40.64 cm | 
| Package 1 Weight | 26.8 kg | 40.0 kg | 37 kg | 
| Unit Type of Package 2 | PAL | PAL | PAL | 
| Number of Units in Package 2 | 1 | 1 | 1 | 
| Package 2 Height | 49.0 cm | 54.5 cm | 40 cm | 
| Package 2 Width | 37.0 cm | 40.0 cm | 53 cm | 
| Package 2 Length | 54.5 cm | 57.5 cm | 57 cm | 
| Package 2 Weight | 26.8 kg | 40.0 kg | 39.75 kg | 
| Contractual warranty | |||
| Warranty | 18 months | 18 months | 18 months | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |