SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1040475
Distance Sensor Model:DT500-A311
OEM Spec Ref
Mechanics/electronics
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Supply voltage Vs | DC 10 V … 30 V, reverse polarity protected
UV ≥ DC 24 V for devices with heating |
Ripple | 5 Vpp 1) |
Power consumption | Typ. 3 W |
Initialization time | 500 ms |
Housing material | Metal (Aluminum die cast) |
Window material | Glass |
Connection type | Male connector, M12, 5-pin |
Weight | 1,000 g |
Dimensions (W x H x D) | 69 mm x 50 mm x 153 mm |
Enclosure rating | IP65 |
Protection class | II 2) |
[/fusion_table]
- 1) May not fall short of or exceed VS tolerances.
- 2) Reference voltage DC 32 V.
Performance
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Measuring range | 0.2 m … 7 m, 90 % remission 1) 2)
0.8 m … 7 m, 6 % remission 1) 2) |
Target | Natural objects |
Resolution | 12 bit |
Repeatability | 1 mm 3) 4) |
Accuracy | ± 3 mm |
Response time | 150 ms |
Output time | 150 ms |
Light source | Laser, red 5) visible red light |
Laser class | 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) |
Typ. light spot size (distance) | 10 mm (at 7 m)
45 mm (at 30 m) 100 mm (at 70 m) |
[/fusion_table]
- 1) In ambient light, max. 1 klx of constant light.
- 2) Unique up to 7 m.
- 3) 6 % … 90 % remission.
- 4) Statistical error 1 σ.
- 5) Average service life of 50,000 h at TA = +25 °C.
Interfaces
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
|
|||||||||
Multifunctional input (MF) | > 12 V 2) | ||||||||
Laser-off input | > 12 V |
[/fusion_table]
- 1) Can be configured to the device: 0 mA … 20 mA / 4 mA … 20 mA (max. load resistance = Uv-2 V / 0.0205 A).
- 2) Refer to function MF input.
Ambient data
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Electromagnetic compatibility (EMC) | EN 61000-6-2, EN 55011
EN 60947-5-7: 2003-9 |
Ambient temperature, operation | –10 °C … +45 °C
–10 °C … +75 °C, operation with cooling case |
Ambient temperature, storage | –25 °C … +75 °C |
Temperature drift | Typ. 0.05 mm/K |
Typ. Ambient light immunity | ≤ 3,000 lx |
Mechanical load | Shock: (EN 600 68-2-27 / –2-29)
Sine: (EN 600 68-2-6) Noise: (EN 600 68-2-64) |
[/fusion_table]