Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.

Features

Ultra-stable

The No. 1 Performance Worldwide*1 for Even More Applications

Best Performance in the World*1

E3NX-FA Features 3

Three Technologies That Support High Performance

E3NX-FA Features 4

*1. For performance (sensing distance and minimum sensing object) based on November 2013 OMRON investigation.
*2. Compared with E3X-HD.
*3. Infrared models (E3NX-FAH) are not equipped with GIGA RAY2S.
*4. Compared with E3X-HD for normal operation processing.
*5. Model with 1 output: 30 μs, model with 2 outputs: 32 μs.

Ultra-easy

Easily Handle a Wide Range of Applications with the Press of a Single Button

Consistent Settings for All Users
Smart Tuning Settings [PAT]

E3NX-FA Features 7

Automatic Adjustment to Optimum Incident Level
Wide Light Intensity Adjustment Range from Transparent Objects to Black Workpieces

E3NX-FA Features 8

Wider light intensity adjustment range of 40,000 times (Conventional models*2: 2,000 times) You can automatically adjust the light intensity to an optimum value for stable detection even with saturated or insufficient incident light.
*2. E3X-HD

Ultra-reliable

Two Decision Support Functions to Help You

Visual Displays of the Passing Time and Difference in Incident Levels.
Solution Viewer [PAT]

E3NX-FA Features 11

Selecting Fiber Units

Just about anyone can make a quantitative decision without special skills.

E3NX-FA Features 12

Setting Optimum Thresholds and Modes

You can see the passing time and difference in incident levels to facilitate manual setup.

E3NX-FA Features 13

Visual Information for Fast Workpieces
Change Finder [PAT]

You can confirm changes in displayed values for fast workpieces to accurately set the threshold.

E3NX-FA Features 14

Point
Advanced DPC (Dynamic Power Control) [PAT]

Predictive Maintenance to Reduce Downtime

An alarm output* has been added to the DPC that automatically compensates differences in the incident level. A maintenance signal is output when the incident level drops due to dirt or vibration for use in predictive maintenance. (We recommend DPC for through-beam or retro-reflective models.)
*An alarm output is supported only on models with two outputs.

E3NX-FA Features 16

 

Lineup

Fiber Amplifier Units

Type Connecting
method
Appearance Inputs/
outputs
Model
NPN output PNP output
Standard
models
Pre-wired (2 m) 3161_lu_1_1 1 output E3NX-FA11 2M E3NX-FA41 2M
E3NX-FA11-5 2M *1
Wire-saving Connector 3161_lu_1_2 1 output E3NX-FA6 E3NX-FA8
Advanced
models
Pre-wired (2 m) 3161_lu_1_3 2 outputs
+ 1 input
E3NX-FA21 2M E3NX-FA51 2M
Wire-saving Connector 3161_lu_1_4 1 output
+ 1 input
E3NX-FA7 E3NX-FA9
2 outputs E3NX-FA7TW E3NX-FA9TW
M8 Connector 3161_lu_1_5 1 output
+ 1 input
E3NX-FA24 E3NX-FA54
2 outputs E3NX-FA54TW
Infrared
models
Pre-wired (2 m) 3161_lu_1_7 1 output E3NX-FAH11 2M E3NX-FAH41 2M
Wire-saving Connector 3161_lu_1_8 1 output E3NX-FAH6 E3NX-FAH8
Analog output
models
Pre-wired (2 m) 3161_lu_1_9 2 outputs E3NX-FA11AN 2M E3NX-FA41AN 2M
Model for Sensor
Communications
Unit *2
Connector for Sensor
Communications Unit
3161_lu_1_6 E3NX-FA0
E3NX-FAH0
Connector for Sensor
Communications Unit
Pre-wired (2 m)
3161_lu_1_10 1 output E3NX-FA10 2M E3NX-FA40 2M

[/fusion_table]

*1. This type can prevent mutual interference for two units in the SHS2 mode.
*2. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.

Accessories (Sold Separately)

Wire-saving Connectors (Required for models for Wire-saving Connectors.)

Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Note: Protective stickers are provided.

Type Appearance Cable
length
No. of
conductors
Model Applicable Fiber Amplifier Units
Master Connector 3161_lu_2_1 2 m 4 E3X-CN21 E3NX-FA7
E3NX-FA7TW
E3NX-FA9
E3NX-FA9TW
Slave Connector 3161_lu_2_2 2 E3X-CN22
Master Connector 3161_lu_2_3 3 E3X-CN11 E3NX-FA6
E3NX-FA8
E3NX-FAH6
E3NX-FAH8
Slave Connector 3161_lu_2_4 1 E3X-CN12

[/fusion_table]

Sensor I/O Connectors (Required for models for M8 Connectors.)

Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.

Size Cable Appearance Cable type Model
M8 Standard cable Straight
3161_lu_3_1
2m 4-wire XS3F-M421-402-A
5m XS3F-M421-405-A
L-shaped
3161_lu_3_2
2m XS3F-M422-402-A
5m XS3F-M422-405-A

[/fusion_table]

Mounting Bracket

A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.

Appearance Model Quantity
3161_lu_4_1
E39-L143 1

[/fusion_table]

DIN Track

A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.

Appearance Type Model Quantity
3161_lu_5_1
Shallow type, total length: 1 m PFP-100N 1
Shallow type, total length: 0.5 m PFP-50N
Deep type, total length: 1 m PFP-100N2

[/fusion_table]

End Plate

Two End Plates are provided with the Sensor Communications Unit.
End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required.

Appearance Model Quantity
3161_lu_6_1
PFP-M 1

[/fusion_table]

Cover

Attach these Covers to Amplifier Units.
Order a Cover when required, e.g., if you lose the covers.

Appearance Model Quantity
3161_lu_8_1 E39-G25 FOR E3NX-FA 1

[/fusion_table]

Related Products

Sensor Communications Units

Type Appearance Model
Sensor Communications Unit for EtherCAT 3161_lu_7_1 E3NW-ECT
Sensor Communications Unit for CompoNet 3161_lu_7_2 E3NW-CRT *1
Sensor Communications Unit for CC-Link 3161_lu_7_3 E3NW-CCL
Distributed Sensor Unit *2 3161_lu_7_4 E3NW-DS

[/fusion_table]

Refer to your OMRON website for details.
*1. E3NX-FAH0 can not be connected.
*2. The Distributed Sensor Unit can be connected to any of the Sensor Communications Units.

EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
CompoNet is a registered trademark of the ODVA.
CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association.

 

Specifications

Standard models/ Advanced models/ Infrared models

Type Standard models
NPN output E3NX-FA11 E3NX-FA6 E3NX-FA11-5 *1
PNP output E3NX-FA41 E3NX-FA8
Connecting method Pre-wired Wire-saving Connector Pre-wired
Inputs/
outputs
Outputs 1 output
External inputs
Light source (wavelength) Red, 4-element LED (625 nm)
Power supply voltage 10 to 30 VDC, including 10% ripple (p-p)
Power consumption *2 At Power supply voltage of 24 VDC
Standard Models:
Normal mode: 840 mW max. (Current consumption at 35 mA max.)
Eco function ON: 650 mW max. (Current consumption at 27 mA max.)
Eco function LO: 750 mW max. (Current consumption at 31 mA max.)Advanced Models or Model for Sensor Communications Unit:
Normal mode: 920 mW max. (Current consumption at 38 mA max.)
Eco function ON: 680 mW max. (Current consumption at 28 mA max.)
Eco function LO: 800 mW max. (Current consumption at 33 mA max.)Infrared models:
Normal mode: 1080 mW max. (Current consumption at 45 mA max.)
Eco function ON: 920 mW max. (Current consumption at 38 mA max.)
Eco function LO: 1020 mW max. (Current consumption at 42 mA max.)
Control output Load power supply voltage: 30 VDC max., open-collector output
(depends on the NPN/PNP output format)
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max.,
Groups of 4 to 30 Amplifier Units: 20 mA max.
(Residual voltage:
At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.)
OFF current: 0.1 mA max.
External inputs
Indicators 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed.
OUT indicator (orange), L/D indicator (orange), ST indicator (blue),
DPC indicator (green), and OUT selection indicator
(orange, only on models with 2 outputs)
Protection circuits Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection
Response
time
Super-high-speed mode (SHS) Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs
High-speed mode (HS) Operate or reset: 250 μs
Standard mode (Stnd) Operate or reset: 1 ms
Giga-power mode (GIGA) Operate or reset: 16 ms