Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.
Features
Ultra-stable
The No. 1 Performance Worldwide*1 for Even More Applications
Best Performance in the World*1

Three Technologies That Support High Performance
*1. For performance (sensing distance and minimum sensing object) based on November 2013 OMRON investigation.
*2. Compared with E3X-HD.
*3. Infrared models (E3NX-FAH) are not equipped with GIGA RAY2S.
*4. Compared with E3X-HD for normal operation processing.
*5. Model with 1 output: 30 μs, model with 2 outputs: 32 μs.
Ultra-easy
Easily Handle a Wide Range of Applications with the Press of a Single Button
Consistent Settings for All Users
Smart Tuning Settings [PAT]

Automatic Adjustment to Optimum Incident Level
Wide Light Intensity Adjustment Range from Transparent Objects to Black Workpieces

Wider light intensity adjustment range of 40,000 times (Conventional models*2: 2,000 times) You can automatically adjust the light intensity to an optimum value for stable detection even with saturated or insufficient incident light.
*2. E3X-HD
Ultra-reliable
Two Decision Support Functions to Help You
Visual Displays of the Passing Time and Difference in Incident Levels.
Solution Viewer [PAT]

Selecting Fiber Units
Just about anyone can make a quantitative decision without special skills.

Setting Optimum Thresholds and Modes
You can see the passing time and difference in incident levels to facilitate manual setup.

Visual Information for Fast Workpieces
Change Finder [PAT]
Point
Advanced DPC (Dynamic Power Control) [PAT]
Predictive Maintenance to Reduce Downtime
An alarm output* has been added to the DPC that automatically compensates differences in the incident level. A maintenance signal is output when the incident level drops due to dirt or vibration for use in predictive maintenance. (We recommend DPC for through-beam or retro-reflective models.)
*An alarm output is supported only on models with two outputs.

Lineup
Fiber Amplifier Units
Type | Connecting method |
Appearance | Inputs/ outputs |
Model | |
---|---|---|---|---|---|
NPN output | PNP output | ||||
Standard models |
Pre-wired (2 m) | ![]() |
1 output | E3NX-FA11 2M | E3NX-FA41 2M |
E3NX-FA11-5 2M *1 | — | ||||
Wire-saving Connector | ![]() |
1 output | E3NX-FA6 | E3NX-FA8 | |
Advanced models |
Pre-wired (2 m) | ![]() |
2 outputs + 1 input |
E3NX-FA21 2M | E3NX-FA51 2M |
Wire-saving Connector | ![]() |
1 output + 1 input |
E3NX-FA7 | E3NX-FA9 | |
2 outputs | E3NX-FA7TW | E3NX-FA9TW | |||
M8 Connector | ![]() |
1 output + 1 input |
E3NX-FA24 | E3NX-FA54 | |
2 outputs | — | E3NX-FA54TW | |||
Infrared models |
Pre-wired (2 m) | ![]() |
1 output | E3NX-FAH11 2M | E3NX-FAH41 2M |
Wire-saving Connector | ![]() |
1 output | E3NX-FAH6 | E3NX-FAH8 | |
Analog output models |
Pre-wired (2 m) | ![]() |
2 outputs | E3NX-FA11AN 2M | E3NX-FA41AN 2M |
Model for Sensor Communications Unit *2 |
Connector for Sensor Communications Unit |
![]() |
— | E3NX-FA0 | |
E3NX-FAH0 | |||||
Connector for Sensor Communications Unit Pre-wired (2 m) |
![]() |
1 output | E3NX-FA10 2M | E3NX-FA40 2M |
[/fusion_table]
*1. This type can prevent mutual interference for two units in the SHS2 mode.
*2. A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
Accessories (Sold Separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Note: Protective stickers are provided.
Type | Appearance | Cable length |
No. of conductors |
Model | Applicable Fiber Amplifier Units |
---|---|---|---|---|---|
Master Connector | ![]() |
2 m | 4 | E3X-CN21 | E3NX-FA7 E3NX-FA7TW E3NX-FA9 E3NX-FA9TW |
Slave Connector | ![]() |
2 | E3X-CN22 | ||
Master Connector | ![]() |
3 | E3X-CN11 | E3NX-FA6 E3NX-FA8 E3NX-FAH6 E3NX-FAH8 |
|
Slave Connector | ![]() |
1 | E3X-CN12 |
[/fusion_table]
Sensor I/O Connectors (Required for models for M8 Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Size | Cable | Appearance | Cable type | Model | ||
---|---|---|---|---|---|---|
M8 | Standard cable | Straight |
![]() |
2m | 4-wire | XS3F-M421-402-A |
5m | XS3F-M421-405-A | |||||
L-shaped |
![]() |
2m | XS3F-M422-402-A | |||
5m | XS3F-M422-405-A |
[/fusion_table]
Mounting Bracket
A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
![]() |
E39-L143 | 1 |
[/fusion_table]
DIN Track
A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required.
Appearance | Type | Model | Quantity |
---|---|---|---|
![]() |
Shallow type, total length: 1 m | PFP-100N | 1 |
Shallow type, total length: 0.5 m | PFP-50N | ||
Deep type, total length: 1 m | PFP-100N2 |
[/fusion_table]
End Plate
Two End Plates are provided with the Sensor Communications Unit.
End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required.
Appearance | Model | Quantity |
---|---|---|
![]() |
PFP-M | 1 |
[/fusion_table]
Cover
Attach these Covers to Amplifier Units.
Order a Cover when required, e.g., if you lose the covers.
Appearance | Model | Quantity |
---|---|---|
![]() |
E39-G25 FOR E3NX-FA | 1 |
[/fusion_table]
Related Products
Sensor Communications Units
Type | Appearance | Model |
---|---|---|
Sensor Communications Unit for EtherCAT | ![]() |
E3NW-ECT |
Sensor Communications Unit for CompoNet | ![]() |
E3NW-CRT *1 |
Sensor Communications Unit for CC-Link | ![]() |
E3NW-CCL |
Distributed Sensor Unit *2 | ![]() |
E3NW-DS |
[/fusion_table]
Refer to your OMRON website for details.
*1. E3NX-FAH0 can not be connected.
*2. The Distributed Sensor Unit can be connected to any of the Sensor Communications Units.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
CompoNet is a registered trademark of the ODVA.
CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association.
last update: May 8, 2019
Specifications
Standard models/ Advanced models/ Infrared models
Type | Standard models | |||
---|---|---|---|---|
NPN output | E3NX-FA11 | E3NX-FA6 | E3NX-FA11-5 *1 | |
PNP output | E3NX-FA41 | E3NX-FA8 | — | |
Connecting method | Pre-wired | Wire-saving Connector | Pre-wired | |
Inputs/ outputs |
Outputs | 1 output | ||
External inputs | — | |||
Light source (wavelength) | Red, 4-element LED (625 nm) | |||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |||
Power consumption *2 | At Power supply voltage of 24 VDC Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.)Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.)Infrared models: Normal mode: 1080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1020 mW max. (Current consumption at 42 mA max.) |
|||
Control output | Load power supply voltage: 30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
|||
External inputs | — | |||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
|||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | |||
Response time |
Super-high-speed mode (SHS) | Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs | ||
High-speed mode (HS) | Operate or reset: 250 μs | |||
Standard mode (Stnd) | Operate or reset: 1 ms | |||
Giga-power mode (GIGA) | Operate or reset: 16 ms |