Specifications

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number

CAD50B7C

CAD50BDC

CAD50CC7C

CAD50E7C

Product Series TeSys
TeSys Deca
TeSys
TeSys Deca
TeSys
TeSys Deca
TeSys
TeSys Deca
product name TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
product type Control relay Control relay Control relay Control relay
product short name CAD CAD CAD CAD
Application field of contactor Control loop Control loop Control loop Control loop
use category DC-13
AC-15
AC-14
DC-13
AC-14
AC-15
AC-15
AC-14
DC-13
AC-14
AC-15
DC-13
Loop contact type 5 NO 5 NO 5 NO 5 NO
Control circuit voltage 24 V AC 50/60 Hz 24 V DC 36 V AC 50/60 Hz 48 V AC 50/60 Hz
Additional information
Rated working voltage [Ue] <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz
Mechanical life 30 Mcycles 30 Mcycles 30 Mcycles 30 Mcycles
operating frequency 180 times/min 180 times/min 180 times/min 180 times/min
action time 12…22 ms coil energization and NO contact closure
4…12 ms coil discharge and NO opening
50…55 ms coil energization and NO contact closure
6…14 ms coil discharge and NO opening
12…22 ms coil energization and NO contact closure
4…12 ms coil discharge and NO opening
12…22 ms coil energization and NO contact closure
4…12 ms coil discharge and NO opening
Control voltage limit Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
Running: 0.7…1.25 Uc
Release: 0.1…0.25 Uc
Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
(~50Hz hold) power consumption (VA) 8VA 50Hz 20°C) N/A 8VA 50Hz 20°C) 8VA 50Hz 20°C)
(~50Hz pickup) power consumption (VA) 70VA 50Hz 20°C) 70VA 50Hz 20°C) 70VA 50Hz 20°C)
Conventional thermal current [Ith] 10 A at <40 °C 10 A at <40 °C 10 A at <40 °C 10 A at <40 °C
Rated making capacity [Irms] 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
Rated short-time withstand current [Icw] 100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
Fuses for use with relays 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1
Insulation resistance > 10 MΩ > 10 MΩ > 10 MΩ > 10 MΩ
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Minimum switching current [Imin] 5 mA 5 mA 5 mA 5 mA
Minimum switching capacity [U min] 17V 17V 17V 17V
non-overlapping time 1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
Wiring capacity Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Tightening torque 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts
high 77 mm 77 mm 77 mm 77 mm
width 45 mm 45 mm 45 mm 45 mm
depth 84 mm 93 mm 84 mm 84 mm
Product Weight 580g 580g 580g 580g
environment
Standards compliant GB 14048.5
IEC 60947-5-1
IEC 60947-5-1
GB 14048.5
GB 14048.5
IEC 60947-5-1
IEC 60947-5-1
GB 14048.5
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
quality mark CE declaration CE declaration CE declaration CE declaration
IP protection class IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529
Protective measures TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068
operating temperature -40…70°C -40…70°C -40…70°C -40…70°C
storage environment temperature -60…80°C -60…80°C -60…80°C -60…80°C
working altitude 3000m 3000m 3000m 3000m
Shock and vibration resistance Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 8.0cm 5.376 cm 8cm 8.0cm
Package 1 Width 9.3 cm 7.884 cm 9.3 cm 9.3 cm
Package 1 Length 5.2 cm 10.441 cm 5.2 cm 5.2 cm
Package 1 Weight 357.88g 510.0g 334.4g 385.4g
Unit Type of Package 2 CAR S02 N/A CAR
Number of Units in Package 2 Twenty four Twenty one Twenty four
Package 2 Height 30.0cm 15.0cm 30.0cm
Package 2 Width 40.0cm 30.0cm 40.0cm
Package 2 Length 15.0cm 40.0cm 15.0cm
Package 2 Weight 8.639 kg 11.2kg 9.3 kg
Unit Type of Package 3 PAL PAL PAL
Number of Units in Package 3 384 336 384
Package 3 Height 60.0cm 60.0cm 60.0cm
Package 3 Width 80.0cm 80.0cm 80.0cm
Package 3 Length 75.0cm 75.0cm 75.0cm
Package 3 Weight 137.624 kg 184.16kg 148.194 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number

CAD50F7C

CAD50M7C

CAD50Q7C

Product Series TeSys
TeSys Deca
TeSys
TeSys Deca
TeSys
TeSys Deca
product name TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
TeSys CAD
TeSys Deca
product type Control relay Control relay Control relay
product short name CAD CAD CAD
Application field of contactor Control loop Control loop Control loop
use category DC-13
AC-14
AC-15
DC-13
AC-15
AC-14
AC-15
AC-14
DC-13
Loop contact type 5 NO 5 NO 5 NO
Control circuit voltage 110V AC 50/60Hz 230V AC 50/60Hz 380 V AC 50/60 Hz
Additional information
Rated working voltage [Ue] <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz <= 690 V AC 25…400 Hz
Mechanical life 30 Mcycles 30 Mcycles 30 Mcycles
operating frequency 180 times/min 180 times/min 180 times/min
action time 12…22 ms coil energization and NO contact closure
4…12 ms coil discharge and NO opening
12…22 ms coil energization and NO contact closure
4…12 ms coil discharge and NO opening
12…22 ms coil energization and NO contact closure
4…12 ms coil discharge and NO opening
Control voltage limit Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
Operation: 0.8…1.1 Uc Operation at 50 Hz
: 0.85…1.1 Uc
Release at 60 Hz: 0.3…0.6 Uc
(~50Hz hold) power consumption (VA) 8VA 50Hz 20°C) 8VA 50Hz 20°C) 8VA 50Hz 20°C)
(~50Hz pickup) power consumption (VA) 70VA 50Hz 20°C) 70VA 50Hz 20°C) 70VA 50Hz 20°C)
Conventional thermal current [Ith] 10 A at <40 °C 10 A at <40 °C 10 A at <40 °C
Rated making capacity [Irms] 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
Rated short-time withstand current [Icw] 100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
100 A – 1 s
120 A – 500 ms
140 A – 100 ms
Fuses for use with relays 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1 10 A gG conforming to IEC 60947-5-1
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1 690 V conforming to IEC 60947-5-1
Insulation resistance > 10 MΩ > 10 MΩ > 10 MΩ
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Minimum switching current [Imin] 5 mA 5 mA 5 mA
Minimum switching capacity [U min] 17V 17V 17V
non-overlapping time 1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
installation method DIN rail installation
base plate installation
DIN rail installation
base plate installation
Chassis mounting
rail installation
Wiring capacity Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Screw-on1
1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1
1…4 mm² Cable option: Flexible wire with screw terminal
2 1…2.5 mm² Cable selection: flexible wire with screw terminal
1 1…4 mm² Cable selection: solid wire without
screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals
Tightening torque 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts 1.7 Nm tightened with bolts
high 77 mm 77 mm 77 mm
width 45 mm 45 mm 45 mm
depth 84 mm 84 mm 84mm
Product Weight 580g 580g 580g
environment
Standards compliant GB 14048.5
IEC 60947-5-1
GB 14048.5
IEC 60947-5-1
IEC 60947-5-1
GB 14048.5
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
quality mark CE declaration CE declaration CE declaration
IP protection class IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529 IP2x front panel conforming to IEC 60529
Protective measures TH conforms to IEC 60068 TH conforms to IEC 60068 TH conforms to IEC 60068
operating temperature -40…70°C -40…70°C -40…70°C
storage environment temperature -60…80°C -60…80°C -60…80°C
working altitude 3000m 3000m 3000m
Shock and vibration resistance Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27
Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6
shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 5.211 cm 5.13cm 8.0cm
Package 1 Width 7.865 cm 7.67cm 9.3 cm
Package 1 Length 9.446 cm 9.28cm 5.2 cm
Package 1 Weight 341.0g 349.0g 370.21g
Unit Type of Package 2 S02 S02 CAR
Number of Units in Package 2 Twenty four Twenty four Twenty four
Package 2 Height 15.0cm 15.0cm 30.0cm
Package 2 Width 30.0cm 30.0cm 40.0cm
Package 2 Length 40.0cm 40.0cm 15.0cm
Package 2 Weight 8.73kg 8.762kg 8.935 kg
Unit Type of Package 3 PAL PAL PAL
Number of Units in Package 3 384 384 384
Package 3 Height 60.0cm 60.0cm 60.0cm
Package 3 Width 80.0cm 80.0cm 80.0cm
Package 3 Length 75.0cm 75.0cm 75.0cm
Package 3 Weight 142.64kg 145.728 kg 142.36kg
contract warranty
Warranty 18 month 18 months 18 months

[/fusion_table]

 

Weight N/A
Dimensions N/A