Main information |
Part Number |
XS630B1PAL2 |
XS630B1NAL2 |
XS630B4PAL2 |
XS630B4NAL2 |
Product Series |
Telemecanique Inductive proximity sensors XS |
Telemecanique Inductive proximity sensors XS |
Telemecanique Inductive proximity sensors XS |
Telemecanique Inductive proximity sensors XS |
Serial Number |
General purpose |
General purpose |
General purpose |
General purpose |
sensor type |
Inductive Proximity Sensors |
Inductive Proximity Sensors |
Inductive Proximity Sensors |
Inductive Proximity Sensors |
Applications |
Mobile devices |
Mobile devices |
Mobile devices |
Mobile devices |
sensor name |
XS6 |
XS6 |
XS6 |
XS6 |
Sensor shape |
M30 Cylindrical |
M30 Cylindrical |
M30 Cylindrical |
M30 Cylindrical |
size |
62 mm |
62 mm |
66 mm |
66 mm |
ontology type |
Fixed |
Fixed |
Fixed |
Fixed |
Detector dark installation acceptance |
Embedded |
Embedded |
Non-flush installation |
Non-flush installation |
Material |
Metal |
Metal |
Metal |
Metal |
output signal type |
Discrete |
Discrete |
Discrete |
Discrete |
Wiring Technology |
3-wire |
3-wire |
3-wire |
3-wire |
Rated sensing distance |
15 mm |
15 mm |
22 mm |
22 mm |
Solid state output function |
1 NO |
1 NO |
1 NO |
1 NO |
output type |
DC |
DC |
DC |
DC |
Solid state output type |
PNP |
NPN |
PNP |
NPN |
Electrical connections |
Cable |
Cable |
Cable |
Cable |
cable length |
2 meters |
2 meters |
2 meters |
2 meters |
Rated supply voltage [Us] |
12…48 V DC and reverse phase protection |
12…48 V DC and reverse phase protection |
12…48 V DC and reverse phase protection |
12…48 V DC and reverse phase protection |
Switching capacity in mA |
<= 200 mA DC and overload and short circuit protected |
<= 200 mA DC and overload and short circuit protected |
<= 200 mA DC and overload and short circuit protected |
<= 200 mA DC and overload and short circuit protected |
IP protection class |
IP68 double insulation according to screwed |
IP68 double insulation according to screwed |
IP68 double insulation according to screwed |
IP68 double insulation according to screwed |
IP69K according to DIN 40050 |
IP69K according to DIN 40050 |
IP69K according to DIN 40050 |
IP69K according to DIN 40050 |
Additional information |
thread type |
M30 x 1.5 |
M30 x 1.5 |
M30 x 1.5 |
M30 x 1.5 |
detection surface |
Front |
Front |
Front |
Front |
Front panel material |
PPS |
PPS |
PPS |
PPS |
Cabinet material |
Nickel-plated brass |
Nickel-plated brass |
Nickel-plated brass |
Nickel-plated brass |
Sensing range |
> 8…15 mm |
> 8…15 mm |
> 15…40mm |
> 15…40mm |
range of motion |
0…12 mm |
0…12 mm |
0…17.6mm |
0…17.6mm |
travel difference |
1…15% of Sr |
1…15% of Sr |
1…15% of Sr |
1…15% of Sr |
Cable composition |
3 x 0.34 mm² |
3 x 0.34 mm² |
3 x 0.34 mm² |
3 x 0.34 mm² |
wire insulation |
Pvc |
Pvc |
Pvc |
Pvc |
LED status |
Output status: LED (yellow) |
Output status: LED (yellow) |
Output status: LED (yellow) |
Output status: LED (yellow) |
Power supply voltage range |
10…58V DC |
10…58V DC |
10…58V DC |
10…58V DC |
On-off level |
<= 500Hz |
<= 500Hz |
<= 500 Hz DC |
<= 500 Hz DC |
Maximum voltage drop |
<2 V (closed) |
<2 V (closed) |
<2 V (closed) |
<2 V (closed) |
current consumption |
<= 10 mA no load |
<= 10 mA no load |
<= 10 mA no load |
<= 10 mA no load |
Maximum delay first up |
10ms |
10ms |
10ms |
10ms |
Maximum delay response |
0.6ms |
0.6ms |
0.6ms |
0.6ms |
Maximum delay recovery |
1.4ms |
1.4ms |
1.4ms |
1.4ms |
logo |
CE |
CE |
CE |
CE |
Thread length |
52 mm |
52 mm |
41 mm |
41 mm |
length |
62 mm |
62 mm |
66 mm |
66 mm |
product weight |
0.21kg |
0.21kg |
0.205 kg |
0.205 kg |
Environment |
certified product |
CSA |
E2 |
E2 |
E2 |
UL |
UL |
CSA |
CSA |
E2 |
CSA |
UL |
UL |
operating temperature |
-25…70°C |
-25…70°C |
-25…70°C |
-25…70°C |
storage environment temperature |
-40…85°C |
-40…85°C |
-40…85°C |
-40…85°C |
Anti-vibration |
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6 |
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6 |
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6 |
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6 |
impact resistance |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
50 gn for 11 ms conforming to IEC 60068-2-27 |
Packaging unit |
Unit Type of Package 1 |
PCE |
PCE |
PCE |
PCE |
Number of Units in Package 1 |
1 |
1 |
1 |
1 |
Package 1 Height |
4.100 cm |
4.500 cm |
4cm |
4.7cm |
Package 1 Width |
9.500 cm |
9.500 cm |
9.5cm |
10.9 cm |
Package 1 Length |
13.200 cm |
13.500 cm |
13.5cm |
20.4cm |
Package 1 Weight |
195.000g |
193.100g |
185g |
186.0g |
Unit Type of Package 2 |
S03 |
S03 |
S02 |
S01 |
Number of Units in Package 2 |
44 |
44 |
22 |
11 |
Package 2 Height |
30.000 cm |
30.000 cm |
15cm |
15.0cm |
Package 2 Width |
30.000 cm |
30.000 cm |
30cm |
15.0cm |
Package 2 Length |
40.000 cm |
40.000 cm |
40cm |
40.0cm |
Package 2 Weight |
9.132 kg |
9.344 kg |
4.388 kg |
2.218 kg |
Unit Type of Package 3 |
P06 |
|
|
|
Number of Units in Package 3 |
352 |
|
|
|
Package 3 Height |
77.000 cm |
|
|
|
Package 3 Width |
80.000 cm |
|
|
|
Package 3 Length |
60.000 cm |
|
|
|
Package 3 Weight |
87.420 kg |
|
|
|
Contract warranty |
Warranty |
18 months |
18 months |
18 months |
18 months |