| General specifications |
| Switching function |
Normally closed (NC) |
| Output type |
NAMUR |
| Rated operating distance |
8 mm |
| Installation |
non-flush |
| Assured operating distance |
0 … 6.48 mm |
| Actual operating distance |
7.2 … 8.8 mm typ. 8 mm |
| Reduction factor rAl |
0.42 |
| Reduction factor rCu |
0.4 |
| Reduction factor r304 |
0.72 |
| Output type |
2-wire |
| Nominal ratings |
| Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
| Switching frequency |
0 … 300 Hz |
| Hysteresis |
1 … 15 typ. 5 % |
| Reverse polarity protection |
reverse polarity protected |
| Short-circuit protection |
yes |
| Current consumption |
|
| Measuring plate not detected |
min. 3 mA |
| Measuring plate detected |
≤ 1 mA |
| Switching state indicator |
all direction LED, yellow |
| Functional safety related parameters |
| Safety Integrity Level (SIL) |
SIL 2 |
| MTTFd |
2040 a |
| Mission Time (TM) |
20 a |
| Diagnostic Coverage (DC) |
0 % |
| Compliance with standards and directives |
| Standard conformity |
|
| NAMUR |
EN 60947-5-6:2000
IEC 60947-5-6:1999 |
| Electromagnetic compatibility |
NE 21:2007 |
| Standards |
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012 |
| Approvals and certificates |
| IECEx approval |
|
| Equipment protection level Ga |
IECEx PTB 11.0037X |
| Equipment protection level Gb |
IECEx PTB 11.0037X |
| Equipment protection level Da |
IECEx PTB 11.0037X |
| Equipment protection level Dc (tc) |
IECEx TUR 21.0018X |
| Equipment protection level Mb |
IECEx PTB 11.0037X |
| ATEX approval |
|
| Equipment protection level Ga |
PTB 00 ATEX 2048 X |
| Equipment protection level Gb |
PTB 00 ATEX 2048 X |
| Equipment protection level Da |
PTB 00 ATEX 2048 X |
| Equipment protection level Dc (tc) |
TÜV 20 ATEX 8524 X |
| UL approval |
|
| Ordinary Location |
E87056 |
| Hazardous Location |
E501628 |
| Control drawing |
116-0452 |
| CCC approval |
|
| Hazardous Location |
2020322315002255 |
| NEPSI approval |
|
| NEPSI certificate |
GYJ16.1393X |
| TIIS approval |
on request |
| ANZEx |
18.3018X |
| KCC approval |
|
| Hazardous Location |
09-AV4BO-0225 |
| Marine approval |
DNVGL TAA00001A5 |
| Ambient conditions |
| Ambient temperature |
-25 … 100 °C (-13 … 212 °F) |
| Storage temperature |
-40 … 100 °C (-40 … 212 °F) |
| Mechanical specifications |
| Connection type |
cable |
| Housing material |
Stainless steel 1.4305 / AISI 303 |
| Sensing face |
PBT |
| Degree of protection |
IP66 / IP67 |
| Cable |
|
| Cable diameter |
6 mm ± 0.2 mm |
| Bending radius |
> 10 x cable diameter |
| Material |
PVC |
| Core cross section |
0.75 mm2 |
| Length |
2 m |
| General information |
| Use in the hazardous area |
see instruction manuals |