General specifications |
Switching function |
Normally closed (NC) |
Output type |
NAMUR |
Rated operating distance |
8 mm |
Installation |
non-flush |
Assured operating distance |
0 … 6.48 mm |
Actual operating distance |
7.2 … 8.8 mm typ. 8 mm |
Reduction factor rAl |
0.42 |
Reduction factor rCu |
0.4 |
Reduction factor r304 |
0.72 |
Output type |
2-wire |
Nominal ratings |
Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
Switching frequency |
0 … 300 Hz |
Hysteresis |
1 … 15 typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
yes |
Current consumption |
|
Measuring plate not detected |
min. 3 mA |
Measuring plate detected |
≤ 1 mA |
Switching state indicator |
all direction LED, yellow |
Functional safety related parameters |
Safety Integrity Level (SIL) |
SIL 2 |
MTTFd |
2040 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Compliance with standards and directives |
Standard conformity |
|
NAMUR |
EN 60947-5-6:2000
IEC 60947-5-6:1999 |
Electromagnetic compatibility |
NE 21:2007 |
Standards |
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates |
IECEx approval |
|
Equipment protection level Ga |
IECEx PTB 11.0037X |
Equipment protection level Gb |
IECEx PTB 11.0037X |
Equipment protection level Da |
IECEx PTB 11.0037X |
Equipment protection level Dc (tc) |
IECEx TUR 21.0018X |
Equipment protection level Mb |
IECEx PTB 11.0037X |
ATEX approval |
|
Equipment protection level Ga |
PTB 00 ATEX 2048 X |
Equipment protection level Gb |
PTB 00 ATEX 2048 X |
Equipment protection level Da |
PTB 00 ATEX 2048 X |
Equipment protection level Dc (tc) |
TÜV 20 ATEX 8524 X |
UL approval |
|
Ordinary Location |
E87056 |
Hazardous Location |
E501628 |
Control drawing |
116-0452 |
CCC approval |
|
Hazardous Location |
2020322315002255 |
NEPSI approval |
|
NEPSI certificate |
GYJ16.1393X |
TIIS approval |
on request |
ANZEx |
18.3018X |
KCC approval |
|
Hazardous Location |
09-AV4BO-0225 |
Marine approval |
DNVGL TAA00001A5 |
Ambient conditions |
Ambient temperature |
-25 … 100 °C (-13 … 212 °F) |
Storage temperature |
-40 … 100 °C (-40 … 212 °F) |
Mechanical specifications |
Connection type |
cable |
Housing material |
Stainless steel 1.4305 / AISI 303 |
Sensing face |
PBT |
Degree of protection |
IP66 / IP67 |
Cable |
|
Cable diameter |
6 mm ± 0.2 mm |
Bending radius |
> 10 x cable diameter |
Material |
PVC |
Core cross section |
0.75 mm2 |
Length |
2 m |
General information |
Use in the hazardous area |
see instruction manuals |